Process Control Instruments, Field Devices and Industrial Automation
ENDRESS+HAUSER CA80AM-AAA11C101 (1)
  • Overview
  • Benefits
  • Specs
  • Related
  • Literature

EH Liquiline System CA80AM Colorimetric high-precision analyzer for online monitoring of Ammonium with Memosens technology. 2 0/4-20 mA outputs, up to 2 measuring channels and up to 4 digital sensor inputs. CSA Approval.

Part# with Options:        CA80AM-AAA11C101
Price with Options:        Please Email us your request for quote   

Options:    

Approval
(1) Approval for EH CA80XX & CAT8X0
Parameter & Measuring Range
(2) Parameter & Measuring Range for EH CA80AM
Sampling Point
(3) Sampling Point for EH CA80AM/PH/CR/FE/NO
Sample Transfer
(4) Sample Transfer for EH CA80AM/PH/CR/FE/NO
Housing & Material
(5) Housing & Material for EH CA80AM/PH/CR/FE/NO/TP
Cable Entry
(6) Cable Entry for EH CA80XX & CAT820
Power Supply
(7) Power Supply for EH CA80AM/PH/CR/FE/NO

  Availability 4 Weeks  ]

Integrated controller with up to 2 measuring channels and digital Memosens technology

Application
  • Digital fieldbuses (Modbus TCP or Modbus RS485) and integrated web server
  • Monitoring and optimization of the cleaning capacity of municipal and industrial wastewater treatment plants
  • Monitoring of the wastewater treatment plant outlet for documentation purposes
  • Monitoring and optimization of activated sludge basins
Your benefits
  • Easy upgrade to measuring station by connecting with up to four Memosens sensors
  • Automatic calibration and cleaning
  • User-configurable measuring, cleaning and calibration intervals
  • Optional cooling module for longer reagent life time
  • Low maintenance costs thanks to long reagent life
  • User-definable measuring ranges
  • Modular design for easily extensible functionality
  • Digital communication for remote access
  • Two-channel device available
Colorimetric measuring principle

After application-specific sample preparation, some of the permeate is pumped into the mixing/ reaction chamber. The specific color reagent is metered exactly in a defined mixture ratio. The chemical reaction causes the characteristic change in the color of the sample. The multispectral photometer measures the level of absorption by the sample or the stain solution at defined wavelengths. The analyzed wavelengths, and their relationships to one another, are parameter- specific.

Based on proportionality the amount of light absorption is a direct indicator of the concentration of the parameter under analysis in the sample. To compensate for any interference influences resulting from turbidity and fouling, as well as from the deterioration and aging of the LEDs, a reference measurement is performed before the actual measurement. This reference signal is subtracted from the measuring signal. The temperature in the photometer is kept constant to ensure a reproducible reaction that takes place with a short period of time.

Measuring Principle Colorimetric
Characteristic Process analyzer for ammonium in aqueous solutions
Comply with standard colorimetric measuring principle - indophenol blue method - following ISO 7150-1, DIN 38406-5 and GB 7481-87
Size Cabinet
793 x 530 x 417 mm
31.22 x 20.87 x 16.42 in
Stand housing
1693 x 530 x 417 mm
66.65 x 20.87 x 16.42 in
Design Open design, cabinet and stand housing
High-Performance plastic ASA-PC, additional stand coated steel
Process temperature 4 ... 40 C (41 ... 104 F)
Ambient temperature 5 ... 40 C (41 ... 104 F)
Process pressure at atmospheric pressure, < 0.2 bar absolute
Probe rate min. 5ml/min (0,17 fl.oz/min)
Consistency of the probe Suspended solids content
Turbitity < 50 NTU, aqueous, homogenized
Specials Easy upgrade to measuring station with up to four digital Memosens sensors
Automatic calibration and cleaning
User-configurable measuring, cleaning and calibration intervals
Optional cooling module for longer reagent shelf life
2 channel version optional
User-definable measuring ranges
Modular design for easily extensible functionality
Digital communication for remote access
Application Monitoring and optimization of the cleaning capacity of municipal and industrial wastewater treatment plants
Monitoring of the wastewater treatment plant outlet for documentation purposes
Monitoring and optimization of activated sludge basins
Power Supply 100 ... 120 VAC / 200 ... 240 VAC 10%
24 VDC 10%
50 1 oder 60 1,2 Hz
Output 2x 0/4 ... 20 mA
Modbus RS485/TCP (optional)
Ethernet (optional)
Alarmrelay
Input 1 or 2 measuring channel
1 ... 4 digitale sensor inputs for sensors with Memosens protocol (optional)
Measurement range 0,05 - 20 mg/l NH4-N
0,5 - 50 mg/l NH4-N
1 - 100 mg/l NH4-N
Consumables Reagents and standard solutions CY80AM as well as cleaner CY800 are necessary for the operation. Regular maintenance is done with the parts of the maintenance kit CAV800.
Export Info
Made inGermany

  • COLORIMETRIC ANALIZERS > GENERAL PURPOSE
    CAT810-AAD1A11 EH Liquiline System CAT810 automatic system for online monitoring of sample conditioning from pressurized pipes and outlets. Self-cleaning backflush filter. Colorimetric measurement. Memosens technology. CSA Approval. ..

  • COLORIMETRIC ANALIZERS > GENERAL PURPOSE
    CAT820-AAE11A2A100A EH Liquiline System CAT820 automatic in-situ filtration system for control of sample conditioning in wastewater treatment plants. Colorimetric measurement. Memosens technology. CSA Approval. ..

  • COLORIMETRIC ANALIZERS > GENERAL PURPOSE
    CAT860-AAE11A2A100TA EH Liquiline System CAT860 automatic in-situ filtration system for control of sample conditioning from inlets in wastewater treatment plants. Colorimetric measurement. Memosens technology. CSA Approval. ..

  • CONDUCTIVITY SENSORS > HAZARDOUS LOCATIONS
    CLS21D-C1E1 EH Condumax CLS21D 2-electrode Digital conductive conductivity sensor for medium and high measuring ranges. Memosens technology. NPT 1" or G1 Process Connection. IP68. ATEX, FM and CSA Approvals. ..

  • ORP ELECTRODES > HAZARDOUS LOCATIONS
    CPS92D-7PB21 EH Orbipore CPS92D digital ORP Memosens glass electrode for heavily polluted media. Corrosion and moisture resistant. 189psi max pressure. Platinum Measuring Surface. IP68. ATEX, FM and CSA approvals. ..

  • OXYGEN SENSORS > GENERAL PURPOSE
    COS61D-AAA1A2 EH Oxymax COS61D digital memosens and optical sensor for measurement of Oxygen (O2) in water, wastewater and utilities applications. Fast and accurate sensor. 0 to 400hPa measuring range. Stainless steel sensor body. G1" thread process connection. NTC tem ..

  • PH & ORP ELECTRODES > HAZARDOUS LOCATIONS
    CPS341D-7A1B1 EH Ceramax CPS341D Digital non-glass pH memosens electrode for hygienic applications. Corrosion, moisture resistant. 87psi max pressure. IP68. ATEX approval. 0-10pH; 0-140oC; 6 bar. ..

  • PHOTOMETRIC SENSORS > GENERAL PURPOSE
    CAS51D-AAA1A2 EH Viomax CAS51D digital memosens photometric sensor for optical nitrate or SAC measurement in water, wastewater and utilities. Self-cleaning functionality. IP68. ..

  • TOROIDAL INDUCTIVE CONDUCTIVITY SENSORS > HAZARDOUS LOCATIONS
    CLS50D-AA1B11 EH Indumax CLS50D Digital Memosens toroidal inductive conductivity sensor for hazardous and high-temperature chemistry applications. Corrosion and moisture resistant. PEEK or PFA material. Integrated Pt1000 temperature sensor. IP67. ATEX, CSA, FM and IECE ..

  • TURBIDITY SENSORS > GENERAL PURPOSE
    CUS51D-AAC1A2 EH Turbimax CUS51D memosens smart sensor for suspended solids and turbidity measurement in water, wastewater and utilities applications. Self-cleaning functionality. Corrosion and moisture resistant. 0 to 150g/l measurement range. Stainless steel sensor. ..

  • TURBIDITY SENSORS > GENERAL PURPOSE
    CUS52D-AA1AA2 EH Turbimax CUS52D Hygienic Memosens Immersion Smart sensor for low and medium turbidity measurement in water. Self-cleaning functionality. 0 to 4000FNUY/NTU measurement range. Stainless steel sensor. G1 and NPT3/4 connection. IP68. ..


B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer, Check and Money Order

Checkout with Paypal

> GENERAL PURPOSE :    46 Items found.
CPS31-1AB2ESA
(378)

ENDRESS+HAUSER  CPS31-1AB2ESA

EH Ceratex CPS31 analog pH glass electrode for application in drinking water and swimming pools. 1 - 12 pH measurement range. Corrosion and moisture resistant. 60 psi max pressure. IP68.

CPS71-1TB2ESA
(389)

ENDRESS+HAUSER  CPS71-1TB2ESA

EH Ceragel CPS71 Analog pH glass electrode for sterile and hygienic applications. Poison resistant. 188psi max pressure. IP68.

CPS72-0PT2ESA
(390)

ENDRESS+HAUSER  CPS72-0PT2ESA

EH Ceragel CPS72 Analog ORP glass electrode for sterile and hygienic applications. Poison resistant. 230psi max pressure. IP68.

CPS31D-7AC21
(287)

ENDRESS+HAUSER  CPS31D-7AC21

EH Memosens CPS31D digital pH glass electrode for application in drinking water and swimming pools. Corrosion and moisture resistant. 60 psi max pressure. IP68.

CPS92-0PB2ESA
(288)

ENDRESS+HAUSER  CPS92-0PB2ESA

EH Orbipore CPS92 analog ORP glass electrode for highly turbid media. IP68. 189psi max pressure. Platinum measuring surface.

CPF201-C1A
(375)

ENDRESS+HAUSER  CPF201-C1A

EH Purisys CPF201 Analog pH glass electrode for pure and ultrapure water. 1-13 pH measurement range. 43.5psi max pressure. IP68.

CM72-AAADB1C1A1A1
(354)

ENDRESS+HAUSER  CM72-AAADB1C1A1A1

EH Liquiline CM72 1 channel small glass electrode transmitter for Memosens Sensors (ph, ORP, conductivity and oxygen). PEEK Housing. IP67 and IP68. 4-20ma Output. CSA Approval.

COS41-8S
(349)

ENDRESS+HAUSER  COS41-8S

EH Oxymax COS41 2-electrode amperometric sensor for the measurement of Dissolved Oxygen (O2) on water and wastewater applications. 0,05 - 20mg/l measuring range. Integrated NTC temperature sensor.

CCS50D-AA11BF
(350)

ENDRESS+HAUSER  CCS50D-AA11BF

EH Memosens CCS50D Digital Sensor for Amperometric measurement of dissolved Chlorine Dioxide (Cl2) in process and drinking water. 0-5 to 0-200 mg/l ClO2 range. Integrated 10k NTC temperature sensor.

CLD18-AGCP
(300)

ENDRESS+HAUSER  CLD18-AGCP

EH Smartec CLD18 toroidal system for inductive conductivity measurement in hygienic applications. Includes compact transmitter and Stainless steel Pt1000 temperature sensor. 200 S/cm - 1000 mS/cm measurement range. IP69.

CLS54D-AAMV5A2A
(301)

ENDRESS+HAUSER  CLS54D-AAMV5A2A

EH Indumax CLS54D Digital Memosens toroidal conductivity sensor for hygienic and sterile applications. Inductive cell. Corrosion and moisture resistant. DN50 Process Connection. PEEK material. Integrated Pt1000 temperature sensor. IP68.

CCS140-A
(171)

ENDRESS+HAUSER  CCS140-A

EH CCS140 analog free chlorine disinfection sensor for industrial and pool water treatment. Amperometric and membrane-covered. 0,05 - 20ppm free chlorine measurement range (pH 4 - 8,2). Optional NTC-temperature sensor. For installation in the CCA250 assembly.

CCS240-N
(329)

ENDRESS+HAUSER  CCS240-N

EH CCS240 Analog disinfection sensor for standard measurement of Chlorine Dioxide (Cl2) 0,05 - 20ppm. Amperometric and membrane-covered. NTC-temperature sensor.

CM82-AAXAB2C1A1A1
(355)

ENDRESS+HAUSER  CM82-AAXAB2C1A1A1

EH Liquiline CM82 1 channel small glass electrode transmitter for Memosens Sensors (ph, ORP, conductivity, oxygen and chlorine). Configurable multiparameter. PEEK Housing. IP67 and IP68. 4-20ma and HART Outputs. Optional Bluetooth. CSA Approval.

CCS120-AS0
(170)

ENDRESS+HAUSER  CCS120-AS0

EH CCS120 analog total chlorine (HOCl, OCl, chloramines) disinfection sensor for all water and wastewater applications. 0,1 - 10ppm total chlorine measurement range (pH 6,5 - 9,5). NPT 3/4" Thread. Includes NTC-temperature sensor and TOP68 plug-in head.



 
COS61-A0F0
(180)

ENDRESS+HAUSER  COS61-A0F0

EH Oxymax COS61 dissolved and optical sensor for the measurement of Oxygen (O2) in water, wastewater and utilities applications. High performance sensor: Fast and accurate. 0 to 400hPa measuring range. Stainless steel sensor body. G1" thread process connection. NTC temperature sensor included.

CYZ71D-AAB110
(273)

ENDRESS+HAUSER  CYZ71D-AAB110

EH Memobase Plus CYZ71D multichannel multiparameter software for liquid analysis with digital Memosens sensors. Includes USB cable, sensor connection box MemoLink and Memosens lab cable CYK20 optionally.

COS22-AA1A2B22
(177)

ENDRESS+HAUSER  COS22-AA1A2B22

EH Oxymax COS22 analog sensor for the measurement of Oxygen (O2) with long-term stability for frequent sterilizations and autoclavability. 0 to 400 hPa (0 to 6 psi) measuring range. Fluorelastomer FDA Process Sealing. Integrated temperature sensor.

CLD134-E00030AA1
(304)

ENDRESS+HAUSER  CLD134-E00030AA1

EH Smartec CLD134 toroidal system for inductive conductivity measurement in hygienic applications. Includes compact transmitter and Stainless steel Pt1000 temperature sensor. 100 S/cm - 2000 mS/cm measurement range. IP67.

COS61D-AAA1A2
(181)

ENDRESS+HAUSER  COS61D-AAA1A2

EH Oxymax COS61D digital memosens and optical sensor for measurement of Oxygen (O2) in water, wastewater and utilities applications. Fast and accurate sensor. 0 to 400hPa measuring range. Stainless steel sensor body. G1" thread process connection. NTC temperature sensor included.

Page: 1 | 2 | 3 | All