InstrumentsAndControl.com Logo | Home
| About Us
| Contact Us
| Get a Quote
| Documents
| Videos
| Subscribe to InstrumentsAndControl.com Newsletter
Shopping Cart
       Worldwide Shipping Reseller & Volume Discounts   Mobile view      LinkedIn Joe Camero profile  Xing Joe Camero profile  Facebook profile of Gas Detectors USA 
281­-609­-7170
Call Us! 9am-5pm CST
Process Control Instruments, Field Devices and Industrial Automation
         
PRODUCTS & SERVICES

InstrumentsAndControl.com is a provider of process control instruments and field devices for Oil & Gas, Industrial Machinery, Pipelines, Custody Transfer, Tank Gauging, Waste Processing, Water Treatment Plants, Burner Management Systems and Incinerators, Conveyor Control, Food & Beverage, Motor, Pump & Compressor Control, Wireless Telemetry, Data Logging, Real-Time Process Data to Web.

We are an online distribution channel of genuine manufactured instruments such as

  • Flow Transmitters, Indicators, Sensors and Switches.
  • Pressure Switches, Indicators and Transmitters.
  • Level Switches, Indicators and Transmitters.
  • Temperature Elements, Switches and Transmitters.
  • Mass Flow Meters.
  • Density Meters.
  • pH/ORP Analyzers.
  • Disolved Oxygen Analyzers.
  • Turbidity Meters.
SKU#(333) Be the First to Review this Item

ENDRESS+HAUSER  CA80AM-AAA11C101

ANALYSIS / COLORIMETRIC ANALIZERS
GENERAL PURPOSE


 Info/Quote Request
 Shipping Rates
 Volume discount
      



ENDRESS+HAUSER CA80AM-AAA11C101 (1)
  • Overview
  • Benefits
  • Specs
  • Related
  • Documents

EH Liquiline System CA80AM Colorimetric high-precision analyzer for online monitoring of Ammonium with Memosens technology. 2 0/4-20 mA outputs, up to 2 measuring channels and up to 4 digital sensor inputs. CSA Approval.

Part# with Options:        CA80AM-AAA11C101
Price with Options:        Please Email us your request for quote   

Options:    

Approval
(1) Approval for EH CA80XX & CAT8X0
Parameter & Measuring Range
(2) Parameter & Measuring Range for EH CA80AM
Sampling Point
(3) Sampling Point for EH CA80AM & CA80PH
Sample Transfer
(4) Sample Transfer for EH CA80AM & CA80PH
Housing & Material
(5) Housing & Material for EH CA80AM & CA80PH
Cable Entry
(6) Cable Entry for EH CA80XX & CAT820
Power Supply
(7) Power Supply for EH CA80AM & CA80PH

  Availability 4 Weeks  ]

Integrated controller with up to 2 measuring channels and digital Memosens technology

Application
  • Digital fieldbuses (Modbus TCP or Modbus RS485) and integrated web server
  • Monitoring and optimization of the cleaning capacity of municipal and industrial wastewater treatment plants
  • Monitoring of the wastewater treatment plant outlet for documentation purposes
  • Monitoring and optimization of activated sludge basins
Your benefits
  • Easy upgrade to measuring station by connecting with up to four Memosens sensors
  • Automatic calibration and cleaning
  • User-configurable measuring, cleaning and calibration intervals
  • Optional cooling module for longer reagent life time
  • Low maintenance costs thanks to long reagent life
  • User-definable measuring ranges
  • Modular design for easily extensible functionality
  • Digital communication for remote access
  • Two-channel device available
Colorimetric measuring principle

After application-specific sample preparation, some of the permeate is pumped into the mixing/ reaction chamber. The specific color reagent is metered exactly in a defined mixture ratio. The chemical reaction causes the characteristic change in the color of the sample. The multispectral photometer measures the level of absorption by the sample or the stain solution at defined wavelengths. The analyzed wavelengths, and their relationships to one another, are parameter- specific.

Based on proportionality the amount of light absorption is a direct indicator of the concentration of the parameter under analysis in the sample. To compensate for any interference influences resulting from turbidity and fouling, as well as from the deterioration and aging of the LEDs, a reference measurement is performed before the actual measurement. This reference signal is subtracted from the measuring signal. The temperature in the photometer is kept constant to ensure a reproducible reaction that takes place with a short period of time.

Measuring Principle Colorimetric
Characteristic Process analyzer for ammonium in aqueous solutions
Comply with standard colorimetric measuring principle - indophenol blue method - following ISO 7150-1, DIN 38406-5 and GB 7481-87
Size Cabinet
793 x 530 x 417 mm
31.22 x 20.87 x 16.42 in
Stand housing
1693 x 530 x 417 mm
66.65 x 20.87 x 16.42 in
Design Open design, cabinet and stand housing
High-Performance plastic ASA-PC, additional stand coated steel
Process temperature 4 ... 40 C (41 ... 104 F)
Ambient temperature 5 ... 40 C (41 ... 104 F)
Process pressure at atmospheric pressure, < 0.2 bar absolute
Probe rate min. 5ml/min (0,17 fl.oz/min)
Consistency of the probe Suspended solids content
Turbitity < 50 NTU, aqueous, homogenized
Specials Easy upgrade to measuring station with up to four digital Memosens sensors
Automatic calibration and cleaning
User-configurable measuring, cleaning and calibration intervals
Optional cooling module for longer reagent shelf life
2 channel version optional
User-definable measuring ranges
Modular design for easily extensible functionality
Digital communication for remote access
Application Monitoring and optimization of the cleaning capacity of municipal and industrial wastewater treatment plants
Monitoring of the wastewater treatment plant outlet for documentation purposes
Monitoring and optimization of activated sludge basins
Power Supply 100 ... 120 VAC / 200 ... 240 VAC 10%
24 VDC 10%
50 1 oder 60 1,2 Hz
Output 2x 0/4 ... 20 mA
Modbus RS485/TCP (optional)
Ethernet (optional)
Alarmrelay
Input 1 or 2 measuring channel
1 ... 4 digitale sensor inputs for sensors with Memosens protocol (optional)
Measurement range 0,05 - 20 mg/l NH4-N
0,5 - 50 mg/l NH4-N
1 - 100 mg/l NH4-N
Consumables Reagents and standard solutions CY80AM as well as cleaner CY800 are necessary for the operation. Regular maintenance is done with the parts of the maintenance kit CAV800.


  • COLORIMETRIC ANALIZERS > GENERAL PURPOSE
    CA80PH-AAE11C101 EH Liquiline System CA80PH Colorimetric analyzer for monitoring of Orthophosphate with Memosens technology. 2 0/4-20 mA outputs, up to 2 measuring channels and up to 4 digital sensor inputs. CSA Approval...


  • COLORIMETRIC ANALIZERS > GENERAL PURPOSE
    CAT820-AAE11A2A100A EH Liquiline System CAT820 automatic in-situ filtration system for control of sample conditioning in wastewater treatment plants. Colorimetric measurement. Memosens technology. CSA Approval...


  • COLORIMETRIC ANALIZERS > GENERAL PURPOSE
    CAT860-AAE11A2A100TA EH Liquiline System CAT860 automatic in-situ filtration system for control of sample conditioning from inlets in wastewater treatment plants. Colorimetric measurement. Memosens technology. CSA Approval...


  • COLORIMETRIC ANALIZERS > GENERAL PURPOSE
    CAT810-AAD1A11 EH Liquiline System CAT810 automatic system for online monitoring of sample conditioning from pressurized pipes and outlets. Self-cleaning backflush filter. Colorimetric measurement. Memosens technology. CSA Approval...



B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer, Check and Money Order

Checkout with Paypal

> COLORIMETRIC ANALIZERS > GENERAL PURPOSE :    4 Items found.
CAT810-AAD1A11 (337) ENDRESS+HAUSER  CAT810-AAD1A11

EH Liquiline System CAT810 automatic system for online monitoring of sample conditioning from pressurized pipes and outlets. Self-cleaning backflush filter. Colorimetric measurement. Memosens technology. CSA Approval.

  

 

 
CAT820-AAE11A2A100A (335) ENDRESS+HAUSER  CAT820-AAE11A2A100A

EH Liquiline System CAT820 automatic in-situ filtration system for control of sample conditioning in wastewater treatment plants. Colorimetric measurement. Memosens technology. CSA Approval.

  

 

 
CAT860-AAE11A2A100TA (336) ENDRESS+HAUSER  CAT860-AAE11A2A100TA

EH Liquiline System CAT860 automatic in-situ filtration system for control of sample conditioning from inlets in wastewater treatment plants. Colorimetric measurement. Memosens technology. CSA Approval.

  

 

 
CA80PH-AAE11C101 (334) ENDRESS+HAUSER  CA80PH-AAE11C101

EH Liquiline System CA80PH Colorimetric analyzer for monitoring of Orthophosphate with Memosens technology. 2 0/4-20 mA outputs, up to 2 measuring channels and up to 4 digital sensor inputs. CSA Approval.

  

 

 
     NEWS & CASES      
() Reviews | Write One
My Last Viewed
CA80AM-AAA11C101

Industrial Automation Services
Industrial Automation Services with PLC and SCADA



| My Orders | Imprint | Terms and Conditions | Privacy | Contact Us | Get a Quote | Sell Here | Mobile View Mobile view | LinkedIn Joe Camero profile  Xing Joe Camero profile  Facebook profile of Gas Detectors USA  | Newsletter Subscribe to InstrumentsAndControl.com Newsletter |
Powered by: macroKom Industrial B2B e-Commerce Engines
Industrial B2B E-Commerce Infrastructure
   + Deployment Services by Miramar Automation
  • Packaged E-Commerce platform, off-the-shelf storefronts
  • CPQ (Configure Price Quote) Web Services and Product Content Management Tools
  • Integration with backend systems (QuickBooks, StoreQuotes, Order Processing)
  • Customer relationship management (CRM) tools
  • Multi-Store
  • Mobile Site