Process Control Instruments, Field Devices and Industrial Automation
SKU# (334)

ENDRESS+HAUSER  CA80PH-AAE11C101




ENDRESS+HAUSER CA80PH-AAE11C101 (1)
  • Overview
  • Benefits
  • Specs
  • Related
  • Documents

EH Liquiline System CA80PH Colorimetric analyzer for monitoring of Orthophosphate with Memosens technology. 2 0/4-20 mA outputs, up to 2 measuring channels and up to 4 digital sensor inputs. CSA Approval.

Part# with Options:        CA80PH-AAE11C101
Price with Options:        Please Email us your request for quote   

Options:    

Approval
(1) Approval for EH CA80XX & CAT8X0
Parameter & Measuring Range
(2) Parameter & Measuring Range for EH CA80PH
Sampling Point
(3) Sampling Point for EH CA80AM & CA80PH
Sample Transfer
(4) Sample Transfer for EH CA80AM & CA80PH
Housing & Material
(5) Housing & Material for EH CA80AM & CA80PH
Cable Entry
(6) Cable Entry for EH CA80XX & CAT820
Power Supply
(7) Power Supply for EH CA80AM & CA80PH

  Availability 4 Weeks  ]

Integrated controller with up to 2 measuring channels and digital Memosens technology

Application
  • Monitoring and optimization of the cleaning capacity of municipal and industrial wastewater treatment plants
  • Monitoring of the wastewater treatment plant outlet for documentation purposes
  • Monitoring and optimization of activated sludge basins
  • Regulation of precipitant dosage
  • Monitoring of cooling water circuits
  • Monitoring of cooling water circuits
Your benefits
  • Easy upgrade to measuring station by connecting with up to four Memosens sensors
  • Automatic calibration and cleaning
  • User-configurable measuring, cleaning and calibration intervals
  • Cooled version for longer reagent shelf life
  • Low maintenance costs thanks to long reagent life
  • User-definable measuring ranges
  • Modular design for easily extensible functionality
  • Digital communication for remote access
  • Two-channel device available
  • Digital fieldbuses (Profibus DP, Modbus TCP, Modbus RS485 and Ethernet IP) and web server
Colorimetric measuring principle

After application-specific sample preparation, some of the permeate is pumped into the mixing/ reaction chamber. The specific color reagent is metered exactly in a defined mixture ratio. The chemical reaction causes the characteristic change in the color of the sample. The multispectral photometer measures the level of absorption by the sample or the stain solution at defined wavelengths. The analyzed wavelengths, and their relationships to one another, are parameter- specific.

Based on proportionality the amount of light absorption is a direct indicator of the concentration of the parameter under analysis in the sample. To compensate for any interference influences resulting from turbidity and fouling, as well as from the deterioration and aging of the LEDs, a reference measurement is performed before the actual measurement. This reference signal is subtracted from the measuring signal. The temperature in the photometer is kept constant to ensure a reproducible reaction that takes place with a short period of time.

Measuring Principle Colorimetric
Characteristic Process analyzer for orthophosphate in aqueous solutions
Comply with standard colorimetric measuring principle - molybdenum blue method - following DIN EN 1189 or molybdate vanadate method.
Size Cabinet
793 x 530 x 417 mm
31.22 x 20.87 x 16.42 in
Stand housing
1693
Design Open design, cabinet and stand housing
High-Performance plastic ASA-PC, additional stand coated steel
Process temperature 4 ... 40 C (39.2 ... 104 F)
Ambient temperature 5 ... 40C ( 41 ... 104F)
Process pressure at atmospheric pressure, < 0.2 bar
Probe rate min. 5ml/min (0,17 fl.oz/min)
Consistency of the probe Suspended solids content
Turbitity < 50 NTU, aqueous, homogenized
Application Monitoring and optimization of the cleaning capacity of municipal and industrial waste water treatment plants
Power Supply 100 ... 120 VAC / 200 ... 240 VAC 10%
24 VDC 10%
50 1 oder 60 1,2 Hz
Output 2x 0/4 ... 20 mA
Modbus RS485/TCP
Input 1 or 2 measuring channel
1 ... 4 digital sensor inputs for sensors with Memosens protocol (optional)
Measurement range 0.05 ... 2.5 mg/l PO4-P (blue method)
0.05 ... 10 mg/l PO4-P (blue method)
0.5 ... 20 mg/l PO4-P (yellow method)
0.5 ... 50 mg/l PO4-P (yellow method)
Consumables Reagents and standard solutions CY80H as well as cleaner CY800 ( blue method) are necessary for the operation. Regular maintenance is done with the parts of the maintenance kit CAV800.

  • COLORIMETRIC ANALIZERS > GENERAL PURPOSE
    CA80AM-AAA11C101 EH Liquiline System CA80AM Colorimetric high-precision analyzer for online monitoring of Ammonium with Memosens technology. 2 0/4-20 mA outputs, up to 2 measuring channels and up to 4 digital sensor inputs. CSA Approval...


  • COLORIMETRIC ANALIZERS > GENERAL PURPOSE
    CAT820-AAE11A2A100A EH Liquiline System CAT820 automatic in-situ filtration system for control of sample conditioning in wastewater treatment plants. Colorimetric measurement. Memosens technology. CSA Approval...


  • COLORIMETRIC ANALIZERS > GENERAL PURPOSE
    CAT860-AAE11A2A100TA EH Liquiline System CAT860 automatic in-situ filtration system for control of sample conditioning from inlets in wastewater treatment plants. Colorimetric measurement. Memosens technology. CSA Approval...


  • COLORIMETRIC ANALIZERS > GENERAL PURPOSE
    CAT810-AAD1A11 EH Liquiline System CAT810 automatic system for online monitoring of sample conditioning from pressurized pipes and outlets. Self-cleaning backflush filter. Colorimetric measurement. Memosens technology. CSA Approval...



B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer, Check and Money Order

Checkout with Paypal

> COLORIMETRIC ANALIZERS > GENERAL PURPOSE :    34 Items found.
CPS31D-7AC21
(287)

ENDRESS+HAUSER  CPS31D-7AC21

EH Memosens CPS31D digital pH glass electrode for application in drinking water and swimming pools. Corrosion and moisture resistant. 60 psi max pressure. IP68.

CPS92-0PB2ESA
(288)

ENDRESS+HAUSER  CPS92-0PB2ESA

EH Orbipore CPS92 analog ORP glass electrode for highly turbid media. IP68. 189psi max pressure. Platinum measuring surface.

CCS142D-AAS80
(330)

ENDRESS+HAUSER  CCS142D-AAS80

EH Chloromax CCS142D Digital disinfection memosens sensor for determining free chlorine in drinking water applications. Thread NPT 3/4 head. Amperometric and membrane-covered. Corrosion and moisture resistant. Integrated temperature sensor.

CLD18-AGCP
(300)

ENDRESS+HAUSER  CLD18-AGCP

EH Smartec CLD18 toroidal system for inductive conductivity measurement in hygienic applications. Includes compact transmitter and Stainless steel Pt1000 temperature sensor. 200 S/cm - 1000 mS/cm measurement range. IP69.

CLS54D-AAMV5A2A
(301)

ENDRESS+HAUSER  CLS54D-AAMV5A2A

EH Indumax CLS54D Digital Memosens toroidal conductivity sensor for hygienic and sterile applications. Inductive cell. Corrosion and moisture resistant. DN50 Process Connection. PEEK material. Integrated Pt1000 temperature sensor. IP68.

CCS140-A
(171)

ENDRESS+HAUSER  CCS140-A

EH CCS140 analog free chlorine disinfection sensor for industrial and pool water treatment. Amperometric and membrane-covered. 0,05 - 20ppm free chlorine measurement range (pH 4 - 8,2). Optional NTC-temperature sensor. For installation in the CCA250 assembly.

CCS240-N
(329)

ENDRESS+HAUSER  CCS240-N

EH CCS240 Analog disinfection sensor for standard measurement of Chlorine Dioxide (Cl2) 0,05 - 20ppm. Amperometric and membrane-covered. NTC-temperature sensor.

CUE26-A
(320)

ENDRESS+HAUSER  CUE26-A

EH Turbimax CUE26 Handheld turbidity meter for on-site quality control. White Light Measurement. 00.01-1100 NTU/FNU measurement range. ABS NEMA4X Housing. IP67.



 
CUE25-A
(319)

ENDRESS+HAUSER  CUE25-A

EH Turbimax CUE25 Handheld turbidity meter for on-site quality control. Infrared Measurement. 00.01-1100 NTU/FNU measurement range. ABS NEMA4X Housing. IP67.



 
CCS120-AS0
(170)

ENDRESS+HAUSER  CCS120-AS0

EH CCS120 analog total chlorine (HOCl, OCl, chloramines) disinfection sensor for all water and wastewater applications. 0,1 - 10ppm total chlorine measurement range (pH 6,5 - 9,5). NPT 3/4" Thread. Includes NTC-temperature sensor and TOP68 plug-in head.



 
COS61-A0F0
(180)

ENDRESS+HAUSER  COS61-A0F0

EH Oxymax COS61 dissolved and optical sensor for the measurement of Oxygen (O2) in water, wastewater and utilities applications. High performance sensor: Fast and accurate. 0 to 400hPa measuring range. Stainless steel sensor body. G1" thread process connection. NTC temperature sensor included.

CYZ71D-AAB110
(273)

ENDRESS+HAUSER  CYZ71D-AAB110

EH Memobase Plus CYZ71D multichannel multiparameter software for liquid analysis with digital Memosens sensors. Includes USB cable, sensor connection box MemoLink and Memosens lab cable CYK20 optionally.

COS22-AA1A2B22
(177)

ENDRESS+HAUSER  COS22-AA1A2B22

EH Oxymax COS22 analog sensor for the measurement of Oxygen (O2) with long-term stability for frequent sterilizations and autoclavability. 0 to 400 hPa (0 to 6 psi) measuring range. Fluorelastomer FDA Process Sealing. Integrated temperature sensor.

CLD134-E00030AA1
(304)

ENDRESS+HAUSER  CLD134-E00030AA1

EH Smartec CLD134 toroidal system for inductive conductivity measurement in hygienic applications. Includes compact transmitter and Stainless steel Pt1000 temperature sensor. 100 S/cm - 2000 mS/cm measurement range. IP67.

COS61D-AAA1A2
(181)

ENDRESS+HAUSER  COS61D-AAA1A2

EH Oxymax COS61D digital memosens and optical sensor for measurement of Oxygen (O2) in water, wastewater and utilities applications. Fast and accurate sensor. 0 to 400hPa measuring range. Stainless steel sensor body. G1" thread process connection. NTC temperature sensor included.

OUSAF11-AA105A1A10A
(323)

ENDRESS+HAUSER  OUSAF11-AA105A1A10A

EH OUSAF11 Glass-free Optical sensor for the measurement of VIS/NIR absorption, changing phases and suspended solids. G1 and NPT Process Connection. 390-1100 nm wavelenght range. 0-3 AU measurement range.

CCS241-N
(328)

ENDRESS+HAUSER  CCS241-N

EH CCS241 Analog disinfection sensor for trace measurement of Chlorine Dioxide (Cl2) 0,01 - 5ppm. Amperometric and membrane-covered. NTC-temperature sensor.

CCS141-N
(172)

ENDRESS+HAUSER  CCS141-N

EH CCS141 analog free chlorine disinfection trace sensor for drinking and industrial water treatment. Amperometric and membrane-covered. 0,01 - 5ppm free chlorine measurement range (pH 4 - 8,2). Includes NTC-temperature sensor. For installation in the CCA250 assembly.

CAT810-AAD1A11
(337)

ENDRESS+HAUSER  CAT810-AAD1A11

EH Liquiline System CAT810 automatic system for online monitoring of sample conditioning from pressurized pipes and outlets. Self-cleaning backflush filter. Colorimetric measurement. Memosens technology. CSA Approval.

CUE24-A
(318)

ENDRESS+HAUSER  CUE24-A

EH Turbimax CUE24 laboratory turbidity meter for quality control. White Light measurement. 0 - 1000 NTU measurement range. RS232 Output. ABS Housing.



 