Process Control Instruments, Field Devices and Industrial Automation
ENDRESS+HAUSER CAT810-AAD1A11 (1)
  • Overview
  • Benefits
  • Specs
  • Related
  • Literature

EH Liquiline System CAT810 automatic system for online monitoring of sample conditioning from pressurized pipes and outlets. Self-cleaning backflush filter. Colorimetric measurement. Memosens technology. CSA Approval.

Part# with Options:        CAT810-AAD1A11
Price with Options:        Please Email us your request for quote   

Options:    

Approval
(1) Approval for EH CA80XX & CAT8X0
Sampling Module
(2) Sampling Module for EH CAT810
Process Connection Inlet
(3) Process Connection Inlet for EH CAT810
Process Connection Drain
(4) Process Connection Drain for EH CAT810

  Availability 6 Weeks  ]

Control of sample preparation by the Liquiline System CA80 or a time control system

Automatic sample preparation system for supplying process measuring devices with filtered samples from pressure pipes

Application

Liquiline System CAT810 enables the fully automatic collection and filtration of aqueous samples. Thanks to the modular concept, the sample preparation system can be adapted to various different process conditions. There are various order options available for this purpose. The sample preparation system can be optionally installed on a mounting plate or in the analyzer stand of a CA80 analyzer.

The device is designed for use in the following applications:

  • Secondary clarification of communal and industrial purification plants
  • Collection of aqueous samples from industrial processes
Your benefits
  • Robust and reliable: Optional water or compressed air backflushing function for the filter
  • Simple and user-friendly:
    • Control via a CA80 analyzer
    • Alternatively via a time control function
  • Cleaning and maintenance: Removal of filter without using tools
  • Flexible:
    • Modular filter system
    • Accessories for a range of installation conditions
Function

TheLiquiline System CAT810 enables the fully automatic collection and filtration of aqueous samples. The static and dynamic pressure in the process bypass cause the sample to pass through the filter. The filtrate line is connected to the collecting vessel of the downstream analyzer.

Measuring system

A complete sample conditioning system comprises:

Liquiline System CAT810 including filter, with the following depending on the version:

  • Cleaning valve
  • Vent valve
  • Drain valve
  • Mounting plate
  • Sample hose to analyzer

Measuring Principle Colorimetric
Characteristic Automatic sample preparation system for supplying process measuring devices with filtered samples from pressurized pipes
Size Panel version
870 x 372 x 343 mm
34.25 x 14.65 x 13.50 in
Prepared for stand housing CA80
828 x 327 x 327 mm
32.6 x 12.87 x 12.87 in
Basic version
811 x 334 x 131 mm
31.93 x 13.15 x 5.16 in
Design Back-wash filter system with various mounting options:
Panel version
Prepared for stand housing of CA80
Basic version - filter unit
Process temperature 4 to 40 C (39 to 104 F)
Ambient temperature 4 to 40 C (39 to 104 F)
Process pressure 1.5 to 4.0 bar (21.76 to 58.01 psi)
for optional automatic cleaning:
2.0 to 5.0 bar (29.0 to 72.5 psi); but at least 0.5 bar (7.3 psi) > process pressure
Specials Optional back-flush with pressurizd air or water
Controling and parametrition via Lquiline System CA80
Stand-alone version with time-control available
Application Sampling from pressurized pipes
Preliminary and secondary clarification of municipal and industrial wastewater treatment plants
Sampling of aqueous media from industrial processes
Power Supply 100 to 120/200 to 240 V AC 10%, 50/60 Hz
Export Info
Made inGermany

  • COLORIMETRIC ANALIZERS > GENERAL PURPOSE
    CA80AM-AAA11C101 EH Liquiline System CA80AM Colorimetric high-precision analyzer for online monitoring of Ammonium with Memosens technology. 2 0/4-20 mA outputs, up to 2 measuring channels and up to 4 digital sensor inputs. CSA Approval. ..

  • COLORIMETRIC ANALIZERS > GENERAL PURPOSE
    CA80PH-AAE11C101 EH Liquiline System CA80PH Colorimetric analyzer for monitoring of Orthophosphate with Memosens technology. 2 0/4-20 mA outputs, up to 2 measuring channels and up to 4 digital sensor inputs. CSA Approval. ..

  • COLORIMETRIC ANALIZERS > GENERAL PURPOSE
    CAT820-AAE11A2A100A EH Liquiline System CAT820 automatic in-situ filtration system for control of sample conditioning in wastewater treatment plants. Colorimetric measurement. Memosens technology. CSA Approval. ..

  • COLORIMETRIC ANALIZERS > GENERAL PURPOSE
    CAT860-AAE11A2A100TA EH Liquiline System CAT860 automatic in-situ filtration system for control of sample conditioning from inlets in wastewater treatment plants. Colorimetric measurement. Memosens technology. CSA Approval. ..


B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer, Check and Money Order

Checkout with Paypal

> COLORIMETRIC ANALIZERS > GENERAL PURPOSE :    47 Items found.
CPS31-1AB2ESA
(378)

ENDRESS+HAUSER  CPS31-1AB2ESA

EH Ceratex CPS31 analog pH glass electrode for application in drinking water and swimming pools. 1 - 12 pH measurement range. Corrosion and moisture resistant. 60 psi max pressure. IP68.

CPS71-1TB2ESA
(389)

ENDRESS+HAUSER  CPS71-1TB2ESA

EH Ceragel CPS71 Analog pH glass electrode for sterile and hygienic applications. Poison resistant. 188psi max pressure. IP68.

CPS72-0PT2ESA
(390)

ENDRESS+HAUSER  CPS72-0PT2ESA

EH Ceragel CPS72 Analog ORP glass electrode for sterile and hygienic applications. Poison resistant. 230psi max pressure. IP68.

CPS31D-7AC21
(287)

ENDRESS+HAUSER  CPS31D-7AC21

EH Memosens CPS31D digital pH glass electrode for application in drinking water and swimming pools. Corrosion and moisture resistant. 60 psi max pressure. IP68.

CPS92-0PB2ESA
(288)

ENDRESS+HAUSER  CPS92-0PB2ESA

EH Orbipore CPS92 analog ORP glass electrode for highly turbid media. IP68. 189psi max pressure. Platinum measuring surface.

CPF201-C1A
(375)

ENDRESS+HAUSER  CPF201-C1A

EH Purisys CPF201 Analog pH glass electrode for pure and ultrapure water. 1-13 pH measurement range. 43.5psi max pressure. IP68.

CM72-AAADB1C1A1A1
(354)

ENDRESS+HAUSER  CM72-AAADB1C1A1A1

EH Liquiline CM72 1 channel small glass electrode transmitter for Memosens Sensors (ph, ORP, conductivity and oxygen). PEEK Housing. IP67 and IP68. 4-20ma Output. CSA Approval.

COS41-8S
(349)

ENDRESS+HAUSER  COS41-8S

EH Oxymax COS41 2-electrode amperometric sensor for the measurement of Dissolved Oxygen (O2) on water and wastewater applications. 0,05 - 20mg/l measuring range. Integrated NTC temperature sensor.

CCS50D-AA11BF
(350)

ENDRESS+HAUSER  CCS50D-AA11BF

EH Memosens CCS50D Digital Sensor for Amperometric measurement of dissolved Chlorine Dioxide (Cl2) in process and drinking water. 0-5 to 0-200 mg/l ClO2 range. Integrated 10k NTC temperature sensor.

CLD18-AGCP
(300)

ENDRESS+HAUSER  CLD18-AGCP

EH Smartec CLD18 toroidal system for inductive conductivity measurement in hygienic applications. Includes compact transmitter and Stainless steel Pt1000 temperature sensor. 200 S/cm - 1000 mS/cm measurement range. IP69.

CLS54D-AAMV5A2A
(301)

ENDRESS+HAUSER  CLS54D-AAMV5A2A

EH Indumax CLS54D Digital Memosens toroidal conductivity sensor for hygienic and sterile applications. Inductive cell. Corrosion and moisture resistant. DN50 Process Connection. PEEK material. Integrated Pt1000 temperature sensor. IP68.

CCS140-A
(171)

ENDRESS+HAUSER  CCS140-A

EH CCS140 analog free chlorine disinfection sensor for industrial and pool water treatment. Amperometric and membrane-covered. 0,05 - 20ppm free chlorine measurement range (pH 4 - 8,2). Optional NTC-temperature sensor. For installation in the CCA250 assembly.

CCS240-N
(329)

ENDRESS+HAUSER  CCS240-N

EH CCS240 Analog disinfection sensor for standard measurement of Chlorine Dioxide (Cl2) 0,05 - 20ppm. Amperometric and membrane-covered. NTC-temperature sensor.

CM82-AAXAB2C1A1A1
(355)

ENDRESS+HAUSER  CM82-AAXAB2C1A1A1

EH Liquiline CM82 1 channel small glass electrode transmitter for Memosens Sensors (ph, ORP, conductivity, oxygen and chlorine). Configurable multiparameter. PEEK Housing. IP67 and IP68. 4-20ma and HART Outputs. Optional Bluetooth. CSA Approval.

CCS120-AS0
(170)

ENDRESS+HAUSER  CCS120-AS0

EH CCS120 analog total chlorine (HOCl, OCl, chloramines) disinfection sensor for all water and wastewater applications. 0,1 - 10ppm total chlorine measurement range (pH 6,5 - 9,5). NPT 3/4" Thread. Includes NTC-temperature sensor and TOP68 plug-in head.



 
COS61-A0F0
(180)

ENDRESS+HAUSER  COS61-A0F0

EH Oxymax COS61 dissolved and optical sensor for the measurement of Oxygen (O2) in water, wastewater and utilities applications. High performance sensor: Fast and accurate. 0 to 400hPa measuring range. Stainless steel sensor body. G1" thread process connection. NTC temperature sensor included.

CYZ71D-AAB110
(273)

ENDRESS+HAUSER  CYZ71D-AAB110

EH Memobase Plus CYZ71D multichannel multiparameter software for liquid analysis with digital Memosens sensors. Includes USB cable, sensor connection box MemoLink and Memosens lab cable CYK20 optionally.

COS22-AA1A2B22
(177)

ENDRESS+HAUSER  COS22-AA1A2B22

EH Oxymax COS22 analog sensor for the measurement of Oxygen (O2) with long-term stability for frequent sterilizations and autoclavability. 0 to 400 hPa (0 to 6 psi) measuring range. Fluorelastomer FDA Process Sealing. Integrated temperature sensor.

CLD134-E00030AA1
(304)

ENDRESS+HAUSER  CLD134-E00030AA1

EH Smartec CLD134 toroidal system for inductive conductivity measurement in hygienic applications. Includes compact transmitter and Stainless steel Pt1000 temperature sensor. 100 S/cm - 2000 mS/cm measurement range. IP67.

COS61D-AAA1A2
(181)

ENDRESS+HAUSER  COS61D-AAA1A2

EH Oxymax COS61D digital memosens and optical sensor for measurement of Oxygen (O2) in water, wastewater and utilities applications. Fast and accurate sensor. 0 to 400hPa measuring range. Stainless steel sensor body. G1" thread process connection. NTC temperature sensor included.

Page: 1 | 2 | 3 | All