Process Control Instruments, Field Devices and Industrial Automation
ENDRESS+HAUSER CPS71D-7TB2C (1)
  • Overview
  • Benefits
  • Specs
  • Related
  • Literature

EH Ceragel CPS71D Digital pH Memosens glass electrode for sterile and hygienic applications. Poison resistant. 188psi max pressure. NTC 30k temperature sensor. IP68. ATEX, FM and CSA approvals.

Part# with Options:        CPS71D-7TB2C
Price with Options:        Please Email us your request for quote   

Options:    

Application Range
(1) Application Range for EH CPS71D
Shaft Length
(2) Shaft Length for EH CPS71D/76D/96D
Approval
(3) Approval for EH CPS71D

  Availability 4 Weeks  ]

Application
  • Aggressive chemical and hygienic applications
    • Chemical industry
    • Foods
    • Fermenters
    • Biotechnology
    • Pharmaceutical industry
  • Process technology and monitoring of processes with:
    • Rapidly changing pH values
    • High proportion of electrode poisons such as H2S

With ATEX, FM and CSA approval for use in hazardous areas

Your benefits
  • Poison-resistant reference with ion trap, resulting in a very lon service life, bridging electrolyte free of silver ions
  • TP version with pressurized reference, for chemical and fermentation processes
  • TU version for upside-down installation, solidified gel in the internal reference lead
  • Integrated temperature sensor for effective temperature compensation
  • Suitable for CIP/SIP cleaning, autoclavable
  • Biocompatibility: reference electrolyte with certified non-cytotoxic gel
  • Acrylamide-free reference and bridging electrolyte
Other advantages of Memosens technology
    Maximum process safety thanks to non-contact, inductive signal transmission Data security thanks to digital data transmission Very easy to use as sensor data saved in the sensor Recording of sensor load data in the sensor enables predictive maintenance with the Memobase Plus CYZ71D
Measuring principle pH measurement

The pH value is used as a unit of measurement for the acidity or alkalinity of a liquid medium. The membrane glass of the electrode supplies an electrochemical potential which is dependent upon the pH value of the medium. This potential is generated by the selective penetration of H + ions through the outer layer of the membrane. An electrochemical boundary layer with an electric potential forms at this point. An integrated Ag/AgCl reference system serves as the required reference electrode. The transmitter converts the measured voltage into the corresponding pH value using the Nernst equation.

Measuring system

A complete measuring system comprises:

  • pH electrode CPS71D or CPS71
  • Transmitter, e.g. Liquiline CM42, CM44x/R, Mycom S CPM153, Liquisys M CPM2x3
  • Memosens data cable CYK10 for Memosens sensors or CPK9 for analog sensors
  • Immersion, flow or retractable assembly, e.g. Cleanfit CPA871/875

Measuring principle

Glass electrode

Application

Hygienic and sterile applications, process

Characteristic

- resistant against reference poisoning - CIP/SIP and autoclavable - high accuracy - biocompatibility of the gel inside (EHEDG, 3A) - version upside-down installation available - pressurized reference (6 bar) available

Measurement range

pH 0-14

Measuring principle

- ceramic diaphragm - ion-trap

Design

- All shaft lengths with temperature sensor - advanced gel technology - digital electrode with Memosens technology

Material

glass / ceramic

Dimension

Diameter: 12 mm (0.46 inch)
Shaft lengths: 120, 225, 360 and 425 mm
(4.68, 8.77, 14.04 and 16,57 inch)

Process temperature

-15C ... 140C
(5F - 284F)

Process pressure

max. 13 bar
(188 psi)

Temperature sensor

NTC 30k

Ex certification

ATEX
FM
CSA

Connection

Inductive, digital connection head with Memosens technology.

Ingres protection

IP68

Additional certifications

3A, biocompatibility

Export Info
Made inGermany

  • ANALYSIS > MULTIPARAMETER TRANSMITTERS
    CM442-AAM1A1F010A-AA EH Liquiline CM442 1 or 2 channel digital multiparameter (pH, redox, ISFET, conductivity inductive and conductive, dissolved oxygen, nitrate and turbidity) transmitter. 2 Memosens inputs, Up to 4 current and 2 relay outputs. IP66+IP67. NEMA Type 4X enclos ..

  • ANALYSIS > MULTIPARAMETER TRANSMITTERS
    CM444-AAM20A0F010BAA-AA EH Liquiline CM444 4 channel digital multiparameter (pH, redox, ISFET, conductivity inductive and conductive, dissolved oxygen, nitrate and turbidity) transmitter. 4 Memosens inputs, up to 8 current and 4 relay outputs. Polycarbonate Housing. ..

  • ANALYSIS > MULTIPARAMETER TRANSMITTERS
    CM448-AA12A61AABAA-AA EH Liquiline CM448 8 channel digital multiparameter (pH, redox, ISFET, conductivity inductive and conductive, dissolved oxygen, nitrate and turbidity) transmitter. 8 Memosens inputs, up to 8 current and 2 relay outputs. IP67. Polycarbonate Housing. ..

  • PH & ORP ANALIZERS > ASSEMBLY
    CPA111-00A EH Dipfit CPA111 Universal Immersion assembly for the applications in open and closed tanks. DN100 flange connection. Accepts up to 3 pH and ORP sensors. ..

  • PH & ORP ANALIZERS > ASSEMBLY
    CPA140-231A110 EH Dipfit CPA140 immersion assembly for applications with aggressive media. Includes flange connection and holder with bayonet lock. Accepts up to 3 pH and ORP sensors. ..

  • PH & ORP ANALIZERS > ASSEMBLY
    CPA450-0B110 EH Cleanfit CPA450 Manual retractable assembly for water & wastewater, chemical, pulp & paper and power industries. Accepts 12mm DO, pH and ORP sensors. DN32 Process Connection. ..

  • PH & ORP ANALIZERS > ASSEMBLY
    CPA472D-A4A1C1D1 EH Cleanfit CPA472D Manual or automatic process retractable heavy-duty assembly for chemical and power industries. Accepts pH and ORP electrodes. DN50/80 Process Connection. ..

  • PH & ORP ANALIZERS > ASSEMBLY
    CPA473-A3A1A1A7 EH Cleanfit CPA473 Manual or automatic process retractable assembly with ball valve for chemical and industrial wastewater applications. Accepts pH and ORP electrodes. DN50/65 Process Connection. ..

  • PH & ORP ANALIZERS > ASSEMBLY
    CPA474-A3A1A1G7 EH Cleanfit CPA474 Manual or automatic process retractable assembly with ball valve for chemical and industrial wastewater applications. Accepts pH and ORP electrodes. DN50 Process Connection. ..

  • PH & ORP ANALIZERS > ASSEMBLY
    CPA871-AACA1ACB1C EH Cleanfit CPA871 Manual or automatic process retractable compact assembly for the water, wastewater and chemical industries. Suitable for vessels and pipes. Accepts standard 12mm pH and ORP sensors. NPT 1 1/2 or DN40/50/80 Process Connection. ..

  • PH & ORP ANALIZERS > ASSEMBLY
    CPA875-AAC1E1CA1A1A EH Cleanfit CPA875 Manual or automatic process retractable assembly for sterile and hygienic applications. Accepts standard (12mm) pH, ORP, oxygen and NIR sensors. DN25/50/65/100 Process Connection. ..

  • PH ANALIZERS > CABLES
    CYK10-A031 EH CYK10 Memosens Measuring Cable for Digital Sensors. IP68. FM, ATEX and CSA Approvals for Ex. ..


B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer, Check and Money Order

Checkout with Paypal

> HAZARDOUS LOCATIONS :    41 Items found.
CPS41-1AB2SSA
(379)

ENDRESS+HAUSER  CPS41-1AB2SSA

EH Ceraliquid CPS41 analog pH glass electrode for harsh chemical applications and low conductivity media. Up to 145psi max pressure. IP68. ATEX, FM and CSA approvals.

CLS19-A1A1D
(370)

ENDRESS+HAUSER  CLS19-A1A1D

EH Condumax CLS19 2-electrode Analog conductive conductivity sensor for pure and ultrapure water applications. NPT 1/2" Process Connection. IP65. ATEX Approval.

CPS42-0PB2SSA
(381)

ENDRESS+HAUSER  CPS42-0PB2SSA

EH Ceraliquid CPS42 analog ORP glass electrode for harsh chemical applications and low conductivity media. Up to 145psi max pressure. IP68. ATEX, FM and CSA approvals.

CPS12-0NA2ESA
(376)

ENDRESS+HAUSER  CPS12-0NA2ESA

EH Orbisint CPS12 Analog ORP glass electrode sensor for standard applications in process and environmental technology. PTFE diaphragm. -1500 mV to +1500 mV measurement range. 230 psi max pressure. IP68. ATEX, FM and CSA approvals.

CPS12D-7NA2C
(377)

ENDRESS+HAUSER  CPS12D-7NA2C

EH Orbisint CPS12D Digital ORP glass electrode Memosens sensor for standard applications in process and environmental technology. Teflon diaphragm. -1500 mV to +1500 mV measurement range. 16bar max pressure. Pt1000 Temperature sensor. IP68. ATEX, FM and CSA approvals.

CPS92D-7PB21
(289)

ENDRESS+HAUSER  CPS92D-7PB21

EH Orbipore CPS92D digital ORP Memosens glass electrode for heavily polluted media. Corrosion and moisture resistant. 189psi max pressure. Platinum Measuring Surface. IP68. ATEX, FM and CSA approvals.

CPS42D-7PB4AC
(382)

ENDRESS+HAUSER  CPS42D-7PB4AC

EH Ceraliquid CPS42D digital ORP Memosens glass electrode for harsh chemical applications and low conductivity media. Up to 145psi max pressure. IP68. ATEX, FM and CSA approvals.

CPS41D-7AB4AC
(380)

ENDRESS+HAUSER  CPS41D-7AB4AC

EH Ceraliquid CPS41D Memosens digital pH glass electrode for harsh chemical applications and low conductivity media. Up to 145psi max pressure. NTC 30k Temperature Sensor. IP68. ATEX, FM and CSA approvals.

CPS471-2ESB1
(385)

ENDRESS+HAUSER  CPS471-2ESB1

EH Tophit CPS471 analog pH sensor with ISFET electrode for sterile and hygienic applications. Up to 145psi max pressure. IP68. ATEX, FM and CSA approvals.

CPS16D-7AT2C
(187)

ENDRESS+HAUSER  CPS16D-7AT2C

EH Memosens CPS16D digital combined pH and ORP glass electrode for standard applications in process technology and environmental engineering. PTFE diaphragm. Corrosion and moisture resistant. 230 psi max pressure. IP68. ATEX, IEC, FM and CSA approvals.

CPS171D-AA7NTP2
(353)

ENDRESS+HAUSER  CPS171D-AA7NTP2

EH Memosens CPS171D Digital Sensor with glass electrode for pH measurement on hygienic and sterile applications (bioreactors and fermenters). 0 - 14 pH measurement range. 0 to 102 psi process pressure. NTC 30k temperature sensor. ATEX, CSA, FM and IECEx approvals.

CPS491-2ESB2
(387)

ENDRESS+HAUSER  CPS491-2ESB2

EH Tophit CPS491 analog pH sensor with ISFET electrode for fibrous media applications. Unbreakable shaft. Up to 145psi max pressure. IP68. ATEX, FM and CSA approvals.

CPS96D-7BT21
(291)

ENDRESS+HAUSER  CPS96D-7BT21

EH Memosens CPS96D Digital pH and ORP Memosens glass electrode for heavily soiled or fibrous media. Corrosion, moisture and poison resistant. 145psi max pressure. IP68. ATEX, IECEx, FM and CSA approvals.

CPS76D-7BB21
(290)

ENDRESS+HAUSER  CPS76D-7BB21

EH Memosens CPS76D Digital pH and ORP Memosens glass electrode for hygienic and sterile applications. Corrosion, moisture and poison resistant. 188psi max pressure. IP68. ATEX, IECEx, FM and CSA approvals.

CPS471D-721C
(386)

ENDRESS+HAUSER  CPS471D-721C

EH Tophit CPS471D digital pH sensor with Memosens ISFET electrode for sterile and hygienic applications. Up to 145psi max pressure. Pt1000 temperatura sensor. IP68. ATEX, FM and CSA approvals.

CPS72D-7PT2C
(391)

ENDRESS+HAUSER  CPS72D-7PT2C

EH Ceragel CPS72D Digital ORP Memosens glass electrode for sterile and hygienic applications. Poison resistant. 230psi max pressure. IP68. ATEX, FM and CSA approval.

CPS491D-722C
(388)

ENDRESS+HAUSER  CPS491D-722C

EH Tophit CPS4901D digital pH sensor with Memosens ISFET electrode for fibrous media applications. Unbreakable shaft. Up to 145psi max pressure. Pt1000 temperature sensor. IP68. ATEX, FM and CSA approvals.

CPS441-2ESC1
(383)

ENDRESS+HAUSER  CPS441-2ESC1

EH Tophit CPS441 analog pH sensor with ISFET electrode for measurement in blocking media. Up to 145psi max pressure. IP68. ATEX, FM and CSA approvals.

CPS441D-72B1C
(384)

ENDRESS+HAUSER  CPS441D-72B1C

EH Tophit CPS441D Digital pH sensor with Memosens ISFET electrode for measurement in blocking media. Up to 145psi max pressure. IP68. ATEX, FM and CSA approvals.

CLS15-A1A1A
(299)

ENDRESS+HAUSER  CLS15-A1A1A

EH Condumax CLS15 2-electrode Analog conductive conductivity sensor for applications in pure and ultrapure water. 1/2"NPT or 3/4" NPT Process Connection. IP67. ATEX Approval.