Process Control Instruments, Field Devices and Industrial Automation
SKU# (372)

ENDRESS+HAUSER  CM44P-AADINP1M00A0F015BAEA




ENDRESS+HAUSER CM44P-AADINP1M00A0F015BAEA (1)
  • Overview
  • Benefits
  • Specs
  • Related
  • Literature

EH Liquiline CM44P 4 channel multiparameter (pH, redox, ISFET, conductivity inductive and conductive, dissolved oxygen, nitrate and turbidity) transmitter for up to 2 process photometers and 4 Memosens sensors. MIR Spectroscopy measuring principle. 0 to 2,5 AU Absorption and 0 to 200 FTU Turbitity measurement ranges. Up to 8 current output alarm relays and 4 relays included.

Part# with Options:        CM44P-AADINP1M00A0F015BAEA
Price with Options:        Please Email us your request for quote   

Options:    

Approval
(1) Approval for EH Liquiline CM44P
Housing
(2) Housing for EH Liquiline CM44P
Optical Sensor Input
(3) Optical Sensor Input for EH Liquiline CM44P
Sensor Input
(4) Sensor Input for EH Liquiline CM44P
Digital Communication
(5) Digital Communication for EH Liquiline CM44P
Analog Output
(6) Analog Output for EH Liquiline CM44P
Additional Features
(7) Additional Features for EH Liquiline CM44P
Power Supply
(8) Power Supply for EH Liquiline CM44P
Cable Entry Housing
(9) Cable Entry Housing for EH Liquiline CM44P
Female Jack Fieldbus Communication
(10) Female Jack Fieldbus Communication for EH Liquiline CM44P
Cable Entry Set
(11) Cable Entry Set for EH Liquiline CM44P
Calibration
(12) Calibration for EH Liquiline CM44P

  Availability 5 Days  ]

Field device or cabinet device

Application
  • Food and beverages
  • Life science
  • Power stations
  • Chemical industry
  • Other industrial applications
Your benefits
  • Highly flexible:
    • Able to connect up to 2 process photometers
    • Mathematics functions calculate new measured values
    • Digital fieldbuses (HART, PROFIBUS, Modbus, Ethernet/IP) and integrated web server
    • Choice of cleaning function, controller and alarm relay
    • Optional digital or analog inputs/outputs
  • Maximum process safety thanks to standardized operating concept across all devices in the Liquiline, sampler and analyzer platform
  • Fast commissioning thanks to:
    • Memosens: lab-calibrated sensors & hot plug-and-play
    • Preconfigured Liquiline transmitter
    • Easy extension and adaptation
  • Minimum inventory:
    • Cross-platform, modular concept (e.g. identical modules irrespective of parameters)
    • Integration into Fieldcare and W@M facilitates effective asset management

Measuring principle

MIR Spectroscopy

Application

Transmitter for process photometer and Memosens sensors

Characteristic

robust plastic housing
all non-ex

Measurement range

Absorption
0 ... 2,5 AU
max. 50 OD ( depending on the optical pathlength)

Turbitity
0 ... 200 FTU
0 ... 200 ppm DE

Design

1 ... 2 process photometer
0 ... 4 Memosens Input
2...8x current output
alarmrelay
4x relay
SD card for software update and copy & paste of setup

Material

plastic (polycarbonate)

Export Info
Made inUnited States

  • OPTICAL ANALIZERS > ASSEMBLY
    OUA260-BA1B04D1A1A EH OUA260 flow assembly for absorption, color and turbidity measurements with OUSAFXX and OUSTF10 optical sensors. Ultra-hygienic design. ..

  • OPTICAL SENSORS > GENERAL PURPOSE
    OUSAF11-AA105A1A10A EH OUSAF11 Glass-free Optical sensor for the measurement of VIS/NIR absorption, changing phases and suspended solids. G1 and NPT Process Connection. 390-1100 nm wavelenght range. 0-3 AU measurement range. ..

  • OPTICAL SENSORS > GENERAL PURPOSE
    OUSBT66-AA05A1A EH OUSBT66 Cell growth and biomass sensor for the measurement of Hygienic NIR absorption in fermentation and crystallization applications. 0-4 AU measurement range. LED light source. IP68. ..

  • OPTICAL SENSORS > HAZARDOUS LOCATIONS
    OUSAF21-D0C0D1D1D1A1A EH OUSAF21 Optical sensor for the measurement of low color concentrations in water. 390-1100 nm wavelength range. Embedded validation filter. Female NPT Process Connection. 0,75" nominal diameter. FM and ATEX approvals. ..

  • OPTICAL SENSORS > HAZARDOUS LOCATIONS
    OUSAF22-B0C0A EH OUSAF22 Optical sensor combined with OUA260 flow assembly for the measurement of color concentrations in liquids. 390-1100 nm wavelenght range. 0-2,5 AU measurement range. Embedded validation filter. FM and ATEX approvals. ..

  • OPTICAL SENSORS > HAZARDOUS LOCATIONS
    OUSAF44-B0A0 EH OUSAF44 Optical sensor combined with OUA260 flow assembly for the measurement of UV absortion. 254-365 nm wavelenght range. 0-2,5 AU measurement range. CIP, SIP, FM and ATEX approvals. IP65. ..

  • ORP ELECTRODES > HAZARDOUS LOCATIONS
    CPS92D-7PB21 EH Orbipore CPS92D digital ORP Memosens glass electrode for heavily polluted media. Corrosion and moisture resistant. 189psi max pressure. Platinum Measuring Surface. IP68. ATEX, FM and CSA approvals. ..

  • PH & ORP ELECTRODES > HAZARDOUS LOCATIONS
    CPS341D-7A1B1 EH Ceramax CPS341D Digital non-glass pH memosens electrode for hygienic applications. Corrosion, moisture resistant. 87psi max pressure. IP68. ATEX approval. 0-10pH; 0-140oC; 6 bar. ..

  • PH & ORP ELECTRODES > HAZARDOUS LOCATIONS
    CPS76D-7BB21 EH Memosens CPS76D Digital pH and ORP Memosens glass electrode for hygienic and sterile applications. Corrosion, moisture and poison resistant. 188psi max pressure. IP68. ATEX, IECEx, FM and CSA approvals. ..

  • PH ANALIZERS > CABLES
    CYK10-A031 EH CYK10 Memosens Measuring Cable for Digital Sensors. IP68. FM, ATEX and CSA Approvals for Ex. ..

  • PH ELECTRODES > FM
    CPS11D-7AA2C EH Orbisint CPS11D pH Digital Electrode with digital Memosens technology for measurement in process and environmental applications. PTFE diaphragm. Low maintenance and a long operating life. ATEX, IECEx, FM (Class I Div. 2), and CSA approval for use in ha ..

  • TOROIDAL INDUCTIVE CONDUCTIVITY SENSORS > HAZARDOUS LOCATIONS
    CLS50D-AA1B11 EH Indumax CLS50D Digital Memosens toroidal inductive conductivity sensor for hazardous and high-temperature chemistry applications. Corrosion and moisture resistant. PEEK or PFA material. Integrated Pt1000 temperature sensor. IP67. ATEX, CSA, FM and IECE ..


B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer, Check and Money Order

Checkout with Paypal

> ANALYSIS > MULTIPARAMETER TRANSMITTERS :    6 Items found.
CM442R-AAM1A1F01-AA
(346)

ENDRESS+HAUSER  CM442R-AAM1A1F01-AA

EH Liquiline CM442R 1 or 2 channel digital multiparameter (pH, redox, ISFET, conductivity inductive and conductive, dissolved oxygen, nitrate and turbidity) DIN-rail transmitter. 2 Memosens inputs. Up to 4 current and 2 relay outputs. IP20.

CM442-AAM1A1F010A-AA
(174)

ENDRESS+HAUSER  CM442-AAM1A1F010A-AA

EH Liquiline CM442 1 or 2 channel digital multiparameter (pH, redox, ISFET, conductivity inductive and conductive, dissolved oxygen, nitrate and turbidity) transmitter. 2 Memosens inputs, Up to 4 current and 2 relay outputs. IP66+IP67. NEMA Type 4X enclosure.

CM444R-AAM20A0F01-AA
(347)

ENDRESS+HAUSER  CM444R-AAM20A0F01-AA

EH Liquiline CM444R 2 or 4 channel digital multiparameter (pH, redox, ISFET, conductivity inductive and conductive, dissolved oxygen, nitrate and turbidity) DIN-rail transmitter. Up to 4 Memosens inputs. Up to 8 current and 4 relay outputs. IP20.

CM444-AAM20A0F010BAA-AA
(175)

ENDRESS+HAUSER  CM444-AAM20A0F010BAA-AA

EH Liquiline CM444 4 channel digital multiparameter (pH, redox, ISFET, conductivity inductive and conductive, dissolved oxygen, nitrate and turbidity) transmitter. 4 Memosens inputs, up to 8 current and 4 relay outputs. Polycarbonate Housing.

CM448R-AA02A61-AA
(348)

ENDRESS+HAUSER  CM448R-AA02A61-AA

EH Liquiline CM448R 8 channel digital multiparameter (pH, redox, ISFET, conductivity inductive and conductive, dissolved oxygen, nitrate and turbidity) DIN-rail transmitter. Up to 8 Memosens inputs. Up to 8 current and 4 relay outputs. IP20.

CM448-AA12A61AABAA-AA
(176)

ENDRESS+HAUSER  CM448-AA12A61AABAA-AA