Process Control Instruments, Field Devices and Industrial Automation
ENDRESS+HAUSER CPA842-AA1E1AAA1 (1)
  • Overview
  • Benefits
  • Specs
  • Related
  • Literature

EH Unifit CPA842 hygienic process assembly for food and beverage industries. Accepts 12mm pH, ORP, Oxygen (O2), conductivity or cell growth sensors. DN25 or DN50 Process Connection.

Part# with Options:        CPA842-AA1E1AAA1
Price with Options:        Please Email us your request for quote   

Options:    

Approval
(1) Approval for EH CPA842
Material & Surface Wetted Parts
(2) Material & Surface Wetted Parts for EH CPA842
Seals
(3) Seals for EH CPA842
Process Connection
(4) Process Connection for EH CPA842

  Availability 10 Days  ]

Simple - Safe - Hygienic - Reliable

Application
  • Process assembly for 12 mm sensors such as pH glass sensors, pH ISFET and oxygen sensors, etc.
  • Food and beverage industry
  • Life sciences
  • Chemical industry
Your benefits
  • Robust assembly
  • Meets the criteria of 3-A standard 74-05, the European Hygienic Engineering and Design Group (EHEDG) and ASME BPE
  • Suitable for in-place cleanability and in-line steam sterilizability
  • Flush-mounted, gap-free electrode seal (sealing ring)
  • Electropolished surface Ra = 0.38 μm or 0.76 μm (stainless steel 1.4435 (AISI 316 L))
  • Hygienic process connections
  • Easy to adapt to existing process
Mode of operation

The assembly is used as a stationary holder for installing 12mm sensors. It can be installed either vertically or at an angle in pipes or reactors. The assembly protects the sensor and seals it off from the process. It is suitable for:

  • CIP (cleaning in place)
  • SIP (sterilization in place)

The versions in stainless steel 1.4435 (AISI 316 L) and Alloy C22 are autoclavable.

Measuring system

A complete measuring system comprises:

  • Unifit CPA842 assembly
  • 12 mm sensor, e.g.CPS171D, Orbisint CPS11D, CLS82D, Oxymax COS22D or COS81D with or without Memosens technology
  • Transmitter, e.g. Liquiline CM44x
  • measuring cable, e.g. CYK10

Measuring principle

Glass electrode

Application

Food & Beverage, Life Science, Process

Installation

Fixed installation assembly

Characteristic

Open and closed tank, piping.

Design

Hygienic assembly with corresponding process connections - 12 mm electrodes - optional with protection guard - optional with leakage control

Material

Holder: stainless steel
sealing: different materials available, FDA conform, USP88 classVI
- Material certification 3.1.B EN 10204- 3A / EHEDG (steam sterilisability + cleanability) - Surface roughness Ra <0.76 (0.38)

Dimension

29.5 to 82.5 mm
(1.16 to 3.25 inch)

Process temperature

-15 to 140 C
(+5 to 280 F)

Process pressure

max. 16 bar
(232 psi)

Connection

DN25 standard, DN25 B.Braun, Clamp 1.5" (short and long), Clamp 1.5'' angled at 15, 2" Clamp, Varivent Typ N, dairy fitting DN50

Export Info
Made inGermany

  • ANALYSIS > MULTIPARAMETER TRANSMITTERS
    CM442-AAM1A1F010A-AA EH Liquiline CM442 1 or 2 channel digital multiparameter (pH, redox, ISFET, conductivity inductive and conductive, dissolved oxygen, nitrate and turbidity) transmitter. 2 Memosens inputs, Up to 4 current and 2 relay outputs. IP66+IP67. NEMA Type 4X enclos ..

  • ANALYSIS > MULTIPARAMETER TRANSMITTERS
    CM444-AAM20A0F010BAA-AA EH Liquiline CM444 4 channel digital multiparameter (pH, redox, ISFET, conductivity inductive and conductive, dissolved oxygen, nitrate and turbidity) transmitter. 4 Memosens inputs, up to 8 current and 4 relay outputs. Polycarbonate Housing. ..

  • ANALYSIS > MULTIPARAMETER TRANSMITTERS
    CM448-AA12A61AABAA-AA EH Liquiline CM448 8 channel digital multiparameter (pH, redox, ISFET, conductivity inductive and conductive, dissolved oxygen, nitrate and turbidity) transmitter. 8 Memosens inputs, up to 8 current and 2 relay outputs. IP67. Polycarbonate Housing. ..

  • OPTICAL SENSORS > GENERAL PURPOSE
    OUSBT66-AA05A1A EH OUSBT66 Cell growth and biomass sensor for the measurement of Hygienic NIR absorption in fermentation and crystallization applications. 0-4 AU measurement range. LED light source. IP68. ..

  • OXYGEN SENSORS > GENERAL PURPOSE
    COS81D-AAA2CB11 EH Memosens COS81D Digital optical sensor for Oxygen (O2) in Hygienic applications. 0,004 to 30 mg/l measurement range. Stainless steel sensor body. 0 to 190 psi process pressure. Pt100 temperature sensor. ATEX, CSA and IECEx approvals. ..

  • OXYGEN SENSORS > HAZARDOUS LOCATIONS
    COS22D-AA1A2B22 EH Oxymax COS22D digital memosens amperometric sensor for the measurement of Oxygen (O2) in hygienic and sterile applications. 0 to 400 hPa (0 to 6 psi) measuring range. Integrated temperature sensor. ATEX, FM and CSA approvals. ..

  • PH & ORP ELECTRODES > HAZARDOUS LOCATIONS
    CPS16D-7AT2C EH Memosens CPS16D digital combined pH and ORP glass electrode for standard applications in process technology and environmental engineering. PTFE diaphragm. Corrosion and moisture resistant. 230 psi max pressure. IP68. ATEX, IEC, FM and CSA approvals. ..

  • PH & ORP ELECTRODES > HAZARDOUS LOCATIONS
    CPS76D-7BB21 EH Memosens CPS76D Digital pH and ORP Memosens glass electrode for hygienic and sterile applications. Corrosion, moisture and poison resistant. 188psi max pressure. IP68. ATEX, IECEx, FM and CSA approvals. ..

  • PH & ORP ELECTRODES > HAZARDOUS LOCATIONS
    CPS96D-7BT21 EH Memosens CPS96D Digital pH and ORP Memosens glass electrode for heavily soiled or fibrous media. Corrosion, moisture and poison resistant. 145psi max pressure. IP68. ATEX, IECEx, FM and CSA approvals. ..

  • PH ANALIZERS > CABLES
    CYK10-A031 EH CYK10 Memosens Measuring Cable for Digital Sensors. IP68. FM, ATEX and CSA Approvals for Ex. ..

  • PH ELECTRODES > FM
    CPS11D-7AA2C EH Orbisint CPS11D pH Digital Electrode with digital Memosens technology for measurement in process and environmental applications. PTFE diaphragm. Low maintenance and a long operating life. ATEX, IECEx, FM (Class I Div. 2), and CSA approval for use in ha ..

  • PH ELECTRODES > HAZARDOUS LOCATIONS
    CPS171D-AA7NTP2 EH Memosens CPS171D Digital Sensor with glass electrode for pH measurement on hygienic and sterile applications (bioreactors and fermenters). 0 - 14 pH measurement range. 0 to 102 psi process pressure. NTC 30k temperature sensor. ATEX, CSA, FM and IECEx ..


B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer, Check and Money Order

Checkout with Paypal

> PH-ORP-CONDUCTIVITY-OXYGEN ELECTRODES > ASSEMBLY :    31 Items found.
CYH112-AA11A11A1
(365)

ENDRESS+HAUSER  CYH112-AA11A11A1

EH Flexdip CYH112 Modular holder system for water and wastewater sensors and assemblies. Up to 6 bar pressure. Works for floor, wall or rail fixings. UV photometric measuring principle.

CPA640-G311
(129)

ENDRESS+HAUSER  CPA640-G311

EH Ecofit CPA640 Universal compact assembly for installation of 120 mm water management sensors. PVDF or stainless steel 316L. Up to 10 bar pressure. NPT 1/2, 3/4" & 1" Process Connection.

CYA112-AA11A1AA
(364)

ENDRESS+HAUSER  CYA112-AA11A1AA

EH Flexdip CYA112 Immersion Modular assembly for water and wastewater. UV photometric measuring principle. Stainless steel or PVC versions.

CCA151-AAB1
(367)

ENDRESS+HAUSER  CCA151-AAB1

EH Flowfit CCA151 Flow assembly for disinfection measurement in drinking and process water with chlorine dioxide sensors. Plexiglas Housing. Panel, wall or pipe mounting.

CPA442-A1D1B11
(373)

ENDRESS+HAUSER  CPA442-A1D1B11

EH Unifit CPA442 hygienic process assembly for food and beverage industries. Accepts 12mm Oxygen (O2), pH and ORP sensors. DN25 or DN50 Process Connection.

COA250-A
(311)

ENDRESS+HAUSER  COA250-A

EH Cleanfit COA250 flow assembly for Dissolved Oxygen sensors. Wall mounting or unsupported installation in pipes. PVC Material. 871 psi max pressure.

CUA250-B
(184)

ENDRESS+HAUSER  CUA250-B

EH Flowfit CUA250 Turbidity assembly for water and wastewater applications in CUS31/CUS41/CUS51D turbidity sensors. PVC holder body. DN20 or DN50 process connection. Up to 6 bar process pressure.

CCA250-A0
(173)

ENDRESS+HAUSER  CCA250-A0

EH Flowfit CCA250 Flow assembly for free chlorine measurement in drinking, industrial and pool water. Designed to accommodate chlorine, pH and ORP sensors. Plexiglas Housing.

CPA250-A00
(285)

ENDRESS+HAUSER  CPA250-A00

EH Flowfit CPA250 Universal Flow assembly for the water and wastewater industry. Pipe installation. Accepts up to 3 pH and ORP sensors. NPT 1 Process Connection.

CUA120-A
(183)

ENDRESS+HAUSER  CUA120-A

EH CUA 120 Flange Adapter for mounting of CUS turbidity sensors. PVC or Stainless Steel Material. For mounting on weld-on flange. Up to 6 bar process pressure.

CPA111-00A
(284)

ENDRESS+HAUSER  CPA111-00A

EH Dipfit CPA111 Universal Immersion assembly for the applications in open and closed tanks. DN100 flange connection. Accepts up to 3 pH and ORP sensors.

CPA510-0110
(282)

ENDRESS+HAUSER  CPA510-0110

EH DipFit CPA510 immersion assembly for DN50 adapters. Includes bayonet lock-mounted electrode holder. Accepts pH and ORP sensors.

CLA111-00A
(306)

ENDRESS+HAUSER  CLA111-00A

EH Dipfit CLA111 immersion assembly for conductivity sensors in open and closed vessels. Includes DN100 flange connection and bayonet lock.

CPA240-23AA110
(286)

ENDRESS+HAUSER  CPA240-23AA110

EH Flowfit CPA240 Durable Flow assembly for all applications with high temperatures and pressures. Pipe installation. Accepts up to 3 pH and ORP sensors. DN25 or NPT 1/2 Process Connection.

CUA252-AAB111
(393)

ENDRESS+HAUSER  CUA252-AAB111

EH Flowfit CUA252 Turbidity assembly for drinking and process water applications with CUS52D turbidity sensor. Polyethylene holder body. G 1 1/4 process connection. Up to 6 bar process pressure.

CLA140-3A1A110
(305)

ENDRESS+HAUSER  CLA140-3A1A110

EH Dipfit CLA140 immersion assembly for conductivity sensors in applications with aggressive media. Includes flange connection and holder with bayonet lock. Thread G3/4 sensor connection. IP65.

CPA140-231A110
(283)

ENDRESS+HAUSER  CPA140-231A110

EH Dipfit CPA140 immersion assembly for applications with aggressive media. Includes flange connection and holder with bayonet lock. Accepts up to 3 pH and ORP sensors.

CYA251-AAA2A111
(396)

ENDRESS+HAUSER  CYA251-AAA2A111

EH Flowfit CYA251 flow assembly for nitrate/SAC, turbidity and oxygen in water and wastewater. UV photometric measuring principle. PVC Material.

CUA262-AAA121
(394)

ENDRESS+HAUSER  CUA262-AAA121

EH Flowfit CUA262 Turbidity assembly for drinking and process water applications with CUS52D turbidity sensor. Stainless steel holder body. Up to 6 bar process pressure.



 
OUA260-BA1B04D1A1A
(326)

ENDRESS+HAUSER  OUA260-BA1B04D1A1A

EH OUA260 flow assembly for absorption, color and turbidity measurements with OUSAFXX and OUSTF10 optical sensors. Ultra-hygienic design.

Page: 1 | 2 | All