EH Ceraliquid CPS42D digital ORP Memosens glass electrode for harsh chemical applications and low conductivity media. Up to 145psi max pressure. IP68. ATEX, FM and CSA approvals.

Part# with Options:        CPS42D-7PB4AC
Price with Options:        Please Email us your request for quote   

Options:    

Shaft Length
(1) Shaft Length for EH CPS42D
Electrolyte supply
(2) Electrolyte supply for EH CPS41D/42D
Approval
(3) Approval for EH CPS41D/42D/72D

  Availability 3 Weeks  ]

ORP electrodes with ceramic diaphragm and liquid KCl electrolyte

Application

Media with very low conductivity or a high proportion of organic solvents or alcohol:

  • Food industry
  • Biotechnology
  • Laboratory measurements
  • Power plant

With ATEX, FM and CSA approval for application in hazardous areas

Your benefits
  • Liquid KCl electrolyte enabling use at very low conductivities
  • Ceramic diaphragm with defined KCl flow
  • Application under pressures of up to 10 bar / 145 psi with counter pressure
  • Resistant to poisoning thanks to separate reference lead
  • Suitable for CIP / SIP cleaning
  • Three lengths available: 120, 225 and 425 mm / 4.72, 8.86 and 16.73 inches
Further benefits offered by Memosens technology
  • Maximum process safety through contactless inductive signal transmission
  • Data safety through digital data transmission
  • Easy handling due to storage of sensor-specific data
  • Predictive maintenance possible thanks to registration of sensor load data
Measuring principle Redox measurement

The redox potential is a unit of measurement for the state of equilibria between oxidising and reducing components of a medium. Redox potential is measured similarly to the pH value. A platinum or gold electrode is used instead of pH-sensitive membrane glass. Analog to the pH measurement, an integrated Ag/AgCl reference system is used as a reference electrode.

Measuring system

A complete measuring system comprises:

  • CPS42 or CPS42D ORP electrode
  • Transmitter, e.g. Liquisys M CPM223/253 (with Memosens technology for CPS42D)
  • Special measuring cable, e.g. CPK9 or CYK Memosens data cable for CPS42D
  • Immersion, flow or retractable assembly, e.g. Unifit H CPA441

Measuring principle

Sensor ORP / Redox

Application

- Special applications with high requirements with regard to accuracy, speed - rapidly changing composition of media, highly clogging media, low conductivities.

Characteristic

- Digital electrode with Memosens technology - gel-free, refillable electrolyte - greatest accuracy - can be subject to pressure to prevent clogging

Measurement range

-1500 mV - +1500 mV

Measuring principle

- Liquid filled compact electrode with ceramic diaphragm - platinum ring

Dimension

Diameter: 12 mm
Shaft lengths: 120, 225 mm

Process temperature

-15C - 130C

Process pressure

max. 8bar

Ex certification

ATEX
FM
CSA
TIIS

Connection

Inductive transfer of digital signals.

Ingres protection

IP68

Additional certifications

EHEDG

Export Info
Made inGermany

  • ANALYSIS > TRANSMITTERS
    CM42-CAA000EAE00 EH Liquiline M CM42 Two-wire transmitter for Ex and non-Ex areas. One or two analog outputs. FOUNDATION Fieldbus, PROFIBUS PA and HART protocols. ATEX, FM, CSA, NEPSI and TIIS Approvals. ..

  • ANALYSIS > TRANSMITTERS
    CPM223-PR0005 EH Liquisys CPM223 pH and ORP compact 1 channel 4-wire transmitter for analog and digital glass and ISFET sensors. Simple menu and two-point calibration. Two-line display. IP65. CSA Approval. ..

  • ANALYSIS > TRANSMITTERS
    CPM253-PR0005 EH Liquisys CPM253 pH and ORP compact 1 channel 4-wire transmitter for analog and digital Memosens sensors. Simple menu and two-point calibration. Two-line display. PC/ABS housing. CSA Approval. ..

  • ORP ELECTRODES > HAZARDOUS LOCATIONS
    CPS42-0PB2SSA EH Ceraliquid CPS42 analog ORP glass electrode for harsh chemical applications and low conductivity media. Up to 145psi max pressure. IP68. ATEX, FM and CSA approvals. ..

  • PH & ORP ANALIZERS > ASSEMBLY
    CPA111-00A EH Dipfit CPA111 Universal Immersion assembly for the applications in open and closed tanks. DN100 flange connection. Accepts up to 3 pH and ORP sensors. ..

  • PH & ORP ANALIZERS > ASSEMBLY
    CPA250-A00 EH Flowfit CPA250 Universal Flow assembly for the water and wastewater industry. Pipe installation. Accepts up to 3 pH and ORP sensors. NPT 1 Process Connection. ..

  • PH & ORP ANALIZERS > ASSEMBLY
    CPA473-A3A1A1A7 EH Cleanfit CPA473 Manual or automatic process retractable assembly with ball valve for chemical and industrial wastewater applications. Accepts pH and ORP electrodes. DN50/65 Process Connection. ..

  • PH & ORP ANALIZERS > ASSEMBLY
    CPA474-A3A1A1G7 EH Cleanfit CPA474 Manual or automatic process retractable assembly with ball valve for chemical and industrial wastewater applications. Accepts pH and ORP electrodes. DN50 Process Connection. ..

  • PH & ORP ANALIZERS > ASSEMBLY
    CPA640-G311 EH Ecofit CPA640 Universal compact assembly for installation of 120 mm water management sensors. PVDF or stainless steel 316L. Up to 10 bar pressure. NPT 1/2, 3/4" & 1" Process Connection. ..

  • PH ANALIZERS > CABLES
    CPK9-NHA1A EH CPK9 Measuring Cable for Analog Sensors. IP68 ..

  • PH ANALIZERS > CABLES
    CYK10-A031 EH CYK10 Memosens Measuring Cable for Digital Sensors. IP68. FM, ATEX and CSA Approvals for Ex. ..

  • PH-ORP-OXYGEN ELECTRODES > ASSEMBLY
    CPA442-A1D1B11 EH Unifit CPA442 hygienic process assembly for food and beverage industries. Accepts 12mm Oxygen (O2), pH and ORP sensors. DN25 or DN50 Process Connection. ..


B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer, Check and Money Order

Checkout with Paypal

> ORP ELECTRODES > HAZARDOUS LOCATIONS :    41 Items found.
CPS41-1AB2SSA
(379)

ENDRESS+HAUSER  CPS41-1AB2SSA

EH Ceraliquid CPS41 analog pH glass electrode for harsh chemical applications and low conductivity media. Up to 145psi max pressure. IP68. ATEX, FM and CSA approvals.

CLS19-A1A1D
(370)

ENDRESS+HAUSER  CLS19-A1A1D

EH Condumax CLS19 2-electrode Analog conductive conductivity sensor for pure and ultrapure water applications. NPT 1/2" Process Connection. IP65. ATEX Approval.

CPS42-0PB2SSA
(381)

ENDRESS+HAUSER  CPS42-0PB2SSA

EH Ceraliquid CPS42 analog ORP glass electrode for harsh chemical applications and low conductivity media. Up to 145psi max pressure. IP68. ATEX, FM and CSA approvals.

CPS12-0NA2ESA
(376)

ENDRESS+HAUSER  CPS12-0NA2ESA

EH Orbisint CPS12 Analog ORP glass electrode sensor for standard applications in process and environmental technology. PTFE diaphragm. -1500 mV to +1500 mV measurement range. 230 psi max pressure. IP68. ATEX, FM and CSA approvals.

CPS12D-7NA2C
(377)

ENDRESS+HAUSER  CPS12D-7NA2C

EH Orbisint CPS12D Digital ORP glass electrode Memosens sensor for standard applications in process and environmental technology. Teflon diaphragm. -1500 mV to +1500 mV measurement range. 16bar max pressure. Pt1000 Temperature sensor. IP68. ATEX, FM and CSA approvals.

CPS71D-7TB2C
(363)

ENDRESS+HAUSER  CPS71D-7TB2C

EH Ceragel CPS71D Digital pH Memosens glass electrode for sterile and hygienic applications. Poison resistant. 188psi max pressure. NTC 30k temperature sensor. IP68. ATEX, FM and CSA approvals.

CPS92D-7PB21
(289)

ENDRESS+HAUSER  CPS92D-7PB21

EH Orbipore CPS92D digital ORP Memosens glass electrode for heavily polluted media. Corrosion and moisture resistant. 189psi max pressure. Platinum Measuring Surface. IP68. ATEX, FM and CSA approvals.

CPS41D-7AB4AC
(380)

ENDRESS+HAUSER  CPS41D-7AB4AC

EH Ceraliquid CPS41D Memosens digital pH glass electrode for harsh chemical applications and low conductivity media. Up to 145psi max pressure. NTC 30k Temperature Sensor. IP68. ATEX, FM and CSA approvals.

CPS471-2ESB1
(385)

ENDRESS+HAUSER  CPS471-2ESB1

EH Tophit CPS471 analog pH sensor with ISFET electrode for sterile and hygienic applications. Up to 145psi max pressure. IP68. ATEX, FM and CSA approvals.

CPS16D-7AT2C
(187)

ENDRESS+HAUSER  CPS16D-7AT2C

EH Memosens CPS16D digital combined pH and ORP glass electrode for standard applications in process technology and environmental engineering. PTFE diaphragm. Corrosion and moisture resistant. 230 psi max pressure. IP68. ATEX, IEC, FM and CSA approvals.

CPS171D-AA7NTP2
(353)

ENDRESS+HAUSER  CPS171D-AA7NTP2

EH Memosens CPS171D Digital Sensor with glass electrode for pH measurement on hygienic and sterile applications (bioreactors and fermenters). 0 - 14 pH measurement range. 0 to 102 psi process pressure. NTC 30k temperature sensor. ATEX, CSA, FM and IECEx approvals.

CPS491-2ESB2
(387)

ENDRESS+HAUSER  CPS491-2ESB2

EH Tophit CPS491 analog pH sensor with ISFET electrode for fibrous media applications. Unbreakable shaft. Up to 145psi max pressure. IP68. ATEX, FM and CSA approvals.

CPS76D-7BB21
(290)

ENDRESS+HAUSER  CPS76D-7BB21

EH Memosens CPS76D Digital pH and ORP Memosens glass electrode for hygienic and sterile applications. Corrosion, moisture and poison resistant. 188psi max pressure. IP68. ATEX, IECEx, FM and CSA approvals.

CPS96D-7BT21
(291)

ENDRESS+HAUSER  CPS96D-7BT21

EH Memosens CPS96D Digital pH and ORP Memosens glass electrode for heavily soiled or fibrous media. Corrosion, moisture and poison resistant. 145psi max pressure. IP68. ATEX, IECEx, FM and CSA approvals.

CPS471D-721C
(386)

ENDRESS+HAUSER  CPS471D-721C

EH Tophit CPS471D digital pH sensor with Memosens ISFET electrode for sterile and hygienic applications. Up to 145psi max pressure. Pt1000 temperatura sensor. IP68. ATEX, FM and CSA approvals.

CPS72D-7PT2C
(391)

ENDRESS+HAUSER  CPS72D-7PT2C

EH Ceragel CPS72D Digital ORP Memosens glass electrode for sterile and hygienic applications. Poison resistant. 230psi max pressure. IP68. ATEX, FM and CSA approval.

CPS491D-722C
(388)

ENDRESS+HAUSER  CPS491D-722C

EH Tophit CPS4901D digital pH sensor with Memosens ISFET electrode for fibrous media applications. Unbreakable shaft. Up to 145psi max pressure. Pt1000 temperature sensor. IP68. ATEX, FM and CSA approvals.

CPS441-2ESC1
(383)

ENDRESS+HAUSER  CPS441-2ESC1

EH Tophit CPS441 analog pH sensor with ISFET electrode for measurement in blocking media. Up to 145psi max pressure. IP68. ATEX, FM and CSA approvals.

CPS441D-72B1C
(384)

ENDRESS+HAUSER  CPS441D-72B1C

EH Tophit CPS441D Digital pH sensor with Memosens ISFET electrode for measurement in blocking media. Up to 145psi max pressure. IP68. ATEX, FM and CSA approvals.

CLS15-A1A1A
(299)

ENDRESS+HAUSER  CLS15-A1A1A

EH Condumax CLS15 2-electrode Analog conductive conductivity sensor for applications in pure and ultrapure water. 1/2"NPT or 3/4" NPT Process Connection. IP67. ATEX Approval.

Page: 1 | 2 | 3 | All