Process Control Instruments, Field Devices and Industrial Automation
ENDRESS+HAUSER CPS471-2ESB1 (1)
  • Overview
  • Benefits
  • Specs
  • Related
  • Literature

EH Tophit CPS471 analog pH sensor with ISFET electrode for sterile and hygienic applications. Up to 145psi max pressure. IP68. ATEX, FM and CSA approvals.

Part# with Options:        CPS471-2ESB1
Price with Options:        Please Email us your request for quote   

Options:    

Shaft Length
(1) Shaft Length for EH CPS441/471/491
Head
(2) Head for EH CPS471/491

  Availability 3 Days  ]

Sterilizable and autoclavable ISFET sensor for the pH measurement Analog or digital sensors with Memosens technology

Application
  • Hygienic and sterile applications
  • Food industry and pharmaceutical industry
  • Biotechnology
Your benefits
  • Resistant to breaking
    • Sensor body made completely of PEEK
    • Direct installation into the process, reduces effort and costs for sampling and laboratory analysis
  • Certified biocompatibility
  • Double-chamber reference system:
    • poisoning resistant
    • polyacrylamide free gel
  • Application possible at low temperatures
    • Short response time
    • Constantly high accuracy
  • Sterilizable and autoclavable
  • Longer calibration intervals than glass electrodes
    • Lower hysteresis with alternating temperatures
    • Low measuring error after high-temperature loading
    • Almost no acid and alkaline errors
  • With built-in temperature sensor for effective temperature compensation
  • Ideal for CIP processes when combined with an automatic retractable assembly
Further benefits offered by Memosens technology
  • Maximum process safety through contactless inductive signal transmission
  • Data safety through digital data transmission
  • Easy handling thanks to storage of sensor-specific data in the sensor
  • Predictive maintenance possible thanks to registration of sensor load data in the sensor
Measuring principle

Ion-selective, or more generally ion-sensitive field effect transistors (ISFET) were developed in the 1970s as an alternative to the glass electrode for pH measurement.

Basics

Ion-selective field effect transistors use an MOS 1) transistor arrangement (see Fig 1) where the metallic gate (pos. 1) is not a control electrode. Instead, the medium (see Fig 2, pos. 3) in the ISFET is in direct contact with the gate isolator layer (pos. 2).Two strongly N-conducting areas are diffused in P-conducting substrate (see Fig 2, pos. 5) of the semiconductor material (Si). These N-conducting areas are current supplying ("Source", S) and current accepting ("Drain", D) electrodes. The metallic gate electrode (in case of the MOSFET) resp. the medium (in case of the ISFET) forms a capacitor with the substrate below. A potential difference between gate and substrate (U GS ) causes a higher electron density between "Source" and "Drain". A N-conducting channel (pos. 2) is formed, i.e. a drain current (I D ) is induced.

With the ISFET, the medium is in direct contact with the gate isolator layer. Therefore, H + ions available in the medium, which are located in the medium / gate isolator boundary layer, create the electric field (gate potential). Depending on the effect described above, a N-conducting channel is formed and a current between "Source" and "Drain" is induced. Suitable sensor circuits use the dependence on the ion-selective gate potential to create an output signal proportional to the concentration of the ion type.

Measuring system

The complete measuring system comprises at least:

  • ISFET sensor Tophit
  • Measuring cable CPK12 (analog, with TOP68 connection) or CYK10 (digital, with Memosens)
  • Transmitter, e.g. Liquiline CM4x, Liquisys CPM223 (for panel mounting) or Liquisys CPM253 (field instrument) or Mycom CPM153.
  • Assembly
    • Immersion assembly, e.g. Dipfit CPA111
    • Flow assembly, e.g. Flowfit CPA250
    • Retractable assembly, e.g. Cleanfit CPA471 (CPA450 only with CPS471D, CPS491D or special versions CPS471-ESA and CPS491-ESA, --> Ordering information)
    • Fixed installation assembly, e.g. Unifit CPA442

There are additional accessories available depending on the application:

  • Topclean CPC30 or Topcal CPC310 automatic cleaning system
  • Extension cable, VBA, VBM or RM junction box

Measuring principle

ISFET sensor

Application

- Hygienic and sterile applications - non-glass, break-proof - low temperatures - pharmaceuticals, biotechnology - contaminating media

Characteristic

- gel-compact electrode - SIP and autoclavable - rapid response at low temperature - lower amount of maintenance required than with glass - biocompatible gel inside (acryle and polyacrylamide free)- overhead installation

Measurement range

pH 0-14

Measuring principle

Ceramic diaphragm, double chamber reference, double gel

Design

- all shaft lengths with temperature sensor - advanced gel technology

Material

PEEK / metal oxide / ceramic / EPDM

Dimension

Diameter: 12 mm (0.47 inch)
Shaft lengths: 120, 225, 360, 425 mm
(4.72/8.86/14.2/16.7 inch)

Process temperature

-15C ... 135C
(5F - 275F)

Process pressure

max. 10 bar/100C (145 psi/212F)

Temperature sensor

Optional with integrated Pt1000

Ex certification

ATEX
FM

Connection

TOP68 connection head

Ingres protection

IP68

Additional certifications

EHEDG, 3A, biocompatibility

Export Info
Made inGermany

  • ANALYSIS > TRANSMITTERS
    CM42-CAA000EAE00 EH Liquiline M CM42 Two-wire transmitter for Ex and non-Ex areas. One or two analog outputs. FOUNDATION Fieldbus, PROFIBUS PA and HART protocols. ATEX, FM, CSA, NEPSI and TIIS Approvals. ..

  • ANALYSIS > TRANSMITTERS
    CPM223-PR0005 EH Liquisys CPM223 pH and ORP compact 1 channel 4-wire transmitter for analog and digital glass and ISFET sensors. Simple menu and two-point calibration. Two-line display. IP65. CSA Approval. ..

  • ANALYSIS > TRANSMITTERS
    CPM253-PR0005 EH Liquisys CPM253 pH and ORP compact 1 channel 4-wire transmitter for analog and digital Memosens sensors. Simple menu and two-point calibration. Two-line display. PC/ABS housing. CSA Approval. ..

  • PH & ORP ANALIZERS > ASSEMBLY
    CPA111-00A EH Dipfit CPA111 Universal Immersion assembly for the applications in open and closed tanks. DN100 flange connection. Accepts up to 3 pH and ORP sensors. ..

  • PH & ORP ANALIZERS > ASSEMBLY
    CPA250-A00 EH Flowfit CPA250 Universal Flow assembly for the water and wastewater industry. Pipe installation. Accepts up to 3 pH and ORP sensors. NPT 1 Process Connection. ..

  • PH & ORP ANALIZERS > ASSEMBLY
    CPA450-0B110 EH Cleanfit CPA450 Manual retractable assembly for water & wastewater, chemical, pulp & paper and power industries. Accepts 12mm DO, pH and ORP sensors. DN32 Process Connection. ..

  • PH ANALIZERS > CABLES
    CYK10-A031 EH CYK10 Memosens Measuring Cable for Digital Sensors. IP68. FM, ATEX and CSA Approvals for Ex. ..

  • PH ELECTRODES > HAZARDOUS LOCATIONS
    CPS471D-721C EH Tophit CPS471D digital pH sensor with Memosens ISFET electrode for sterile and hygienic applications. Up to 145psi max pressure. Pt1000 temperatura sensor. IP68. ATEX, FM and CSA approvals. ..

  • PH-ORP-OXYGEN ELECTRODES > ASSEMBLY
    CPA442-A1D1B11 EH Unifit CPA442 hygienic process assembly for food and beverage industries. Accepts 12mm Oxygen (O2), pH and ORP sensors. DN25 or DN50 Process Connection. ..


B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer, Check and Money Order

Checkout with Paypal

> HAZARDOUS LOCATIONS :    41 Items found.
CPS41-1AB2SSA
(379)

ENDRESS+HAUSER  CPS41-1AB2SSA

EH Ceraliquid CPS41 analog pH glass electrode for harsh chemical applications and low conductivity media. Up to 145psi max pressure. IP68. ATEX, FM and CSA approvals.

CLS19-A1A1D
(370)

ENDRESS+HAUSER  CLS19-A1A1D

EH Condumax CLS19 2-electrode Analog conductive conductivity sensor for pure and ultrapure water applications. NPT 1/2" Process Connection. IP65. ATEX Approval.

CPS42-0PB2SSA
(381)

ENDRESS+HAUSER  CPS42-0PB2SSA

EH Ceraliquid CPS42 analog ORP glass electrode for harsh chemical applications and low conductivity media. Up to 145psi max pressure. IP68. ATEX, FM and CSA approvals.

CPS12-0NA2ESA
(376)

ENDRESS+HAUSER  CPS12-0NA2ESA

EH Orbisint CPS12 Analog ORP glass electrode sensor for standard applications in process and environmental technology. PTFE diaphragm. -1500 mV to +1500 mV measurement range. 230 psi max pressure. IP68. ATEX, FM and CSA approvals.

CPS12D-7NA2C
(377)

ENDRESS+HAUSER  CPS12D-7NA2C

EH Orbisint CPS12D Digital ORP glass electrode Memosens sensor for standard applications in process and environmental technology. Teflon diaphragm. -1500 mV to +1500 mV measurement range. 16bar max pressure. Pt1000 Temperature sensor. IP68. ATEX, FM and CSA approvals.

CPS71D-7TB2C
(363)

ENDRESS+HAUSER  CPS71D-7TB2C

EH Ceragel CPS71D Digital pH Memosens glass electrode for sterile and hygienic applications. Poison resistant. 188psi max pressure. NTC 30k temperature sensor. IP68. ATEX, FM and CSA approvals.

CPS92D-7PB21
(289)

ENDRESS+HAUSER  CPS92D-7PB21

EH Orbipore CPS92D digital ORP Memosens glass electrode for heavily polluted media. Corrosion and moisture resistant. 189psi max pressure. Platinum Measuring Surface. IP68. ATEX, FM and CSA approvals.

CPS42D-7PB4AC
(382)

ENDRESS+HAUSER  CPS42D-7PB4AC

EH Ceraliquid CPS42D digital ORP Memosens glass electrode for harsh chemical applications and low conductivity media. Up to 145psi max pressure. IP68. ATEX, FM and CSA approvals.

CPS41D-7AB4AC
(380)

ENDRESS+HAUSER  CPS41D-7AB4AC

EH Ceraliquid CPS41D Memosens digital pH glass electrode for harsh chemical applications and low conductivity media. Up to 145psi max pressure. NTC 30k Temperature Sensor. IP68. ATEX, FM and CSA approvals.

CPS16D-7AT2C
(187)

ENDRESS+HAUSER  CPS16D-7AT2C

EH Memosens CPS16D digital combined pH and ORP glass electrode for standard applications in process technology and environmental engineering. PTFE diaphragm. Corrosion and moisture resistant. 230 psi max pressure. IP68. ATEX, IEC, FM and CSA approvals.

CPS171D-AA7NTP2
(353)

ENDRESS+HAUSER  CPS171D-AA7NTP2

EH Memosens CPS171D Digital Sensor with glass electrode for pH measurement on hygienic and sterile applications (bioreactors and fermenters). 0 - 14 pH measurement range. 0 to 102 psi process pressure. NTC 30k temperature sensor. ATEX, CSA, FM and IECEx approvals.

CPS491-2ESB2
(387)

ENDRESS+HAUSER  CPS491-2ESB2

EH Tophit CPS491 analog pH sensor with ISFET electrode for fibrous media applications. Unbreakable shaft. Up to 145psi max pressure. IP68. ATEX, FM and CSA approvals.

CPS76D-7BB21
(290)

ENDRESS+HAUSER  CPS76D-7BB21

EH Memosens CPS76D Digital pH and ORP Memosens glass electrode for hygienic and sterile applications. Corrosion, moisture and poison resistant. 188psi max pressure. IP68. ATEX, IECEx, FM and CSA approvals.

CPS96D-7BT21
(291)

ENDRESS+HAUSER  CPS96D-7BT21

EH Memosens CPS96D Digital pH and ORP Memosens glass electrode for heavily soiled or fibrous media. Corrosion, moisture and poison resistant. 145psi max pressure. IP68. ATEX, IECEx, FM and CSA approvals.

CPS471D-721C
(386)

ENDRESS+HAUSER  CPS471D-721C

EH Tophit CPS471D digital pH sensor with Memosens ISFET electrode for sterile and hygienic applications. Up to 145psi max pressure. Pt1000 temperatura sensor. IP68. ATEX, FM and CSA approvals.

CPS72D-7PT2C
(391)

ENDRESS+HAUSER  CPS72D-7PT2C

EH Ceragel CPS72D Digital ORP Memosens glass electrode for sterile and hygienic applications. Poison resistant. 230psi max pressure. IP68. ATEX, FM and CSA approval.

CPS491D-722C
(388)

ENDRESS+HAUSER  CPS491D-722C

EH Tophit CPS4901D digital pH sensor with Memosens ISFET electrode for fibrous media applications. Unbreakable shaft. Up to 145psi max pressure. Pt1000 temperature sensor. IP68. ATEX, FM and CSA approvals.

CPS441-2ESC1
(383)

ENDRESS+HAUSER  CPS441-2ESC1

EH Tophit CPS441 analog pH sensor with ISFET electrode for measurement in blocking media. Up to 145psi max pressure. IP68. ATEX, FM and CSA approvals.

CPS441D-72B1C
(384)

ENDRESS+HAUSER  CPS441D-72B1C

EH Tophit CPS441D Digital pH sensor with Memosens ISFET electrode for measurement in blocking media. Up to 145psi max pressure. IP68. ATEX, FM and CSA approvals.

CLS15-A1A1A
(299)

ENDRESS+HAUSER  CLS15-A1A1A

EH Condumax CLS15 2-electrode Analog conductive conductivity sensor for applications in pure and ultrapure water. 1/2"NPT or 3/4" NPT Process Connection. IP67. ATEX Approval.

Page: 1 | 2 | 3 | All