Process Control Instruments, Field Devices and Industrial Automation
ENDRESS+HAUSER CPS71-1TB2ESA (1)
  • Overview
  • Benefits
  • Specs
  • Related
  • Literature

EH Ceragel CPS71 Analog pH glass electrode for sterile and hygienic applications. Poison resistant. 188psi max pressure. IP68.

Part# with Options:        CPS71-1TB2ESA
Price with Options:        Please Email us your request for quote   

Options:    

Electrode Type
(1) Electrode Type for EH CPS41/71
Application Range
(2) Application Range for EH CPS71
Shaft Length
(3) Shaft Length for EH CPS41/71
Head
(4) Head for EH CPS71

  Availability 2 Days  ]

Application
  • Aggressive chemical and hygienic applications
    • Chemical industry
    • Foods
    • Fermenters
    • Biotechnology
    • Pharmaceutical industry
  • Process technology and monitoring of processes with:
    • Rapidly changing pH values
    • High proportion of electrode poisons such as H2S

With ATEX, FM and CSA approval for use in hazardous areas

Your benefits
  • Poison-resistant reference with ion trap, resulting in a very lon service life, bridging electrolyte free of silver ions
  • TP version with pressurized reference, for chemical and fermentation processes
  • TU version for upside-down installation, solidified gel in the internal reference lead
  • Integrated temperature sensor for effective temperature compensation
  • Suitable for CIP/SIP cleaning, autoclavable
  • Biocompatibility: reference electrolyte with certified non-cytotoxic gel
  • Acrylamide-free reference and bridging electrolyte
Other advantages of Memosens technology
    Maximum process safety thanks to non-contact, inductive signal transmission Data security thanks to digital data transmission Very easy to use as sensor data saved in the sensor Recording of sensor load data in the sensor enables predictive maintenance with the Memobase Plus CYZ71D
Measuring principle pH measurement

The pH value is used as a unit of measurement for the acidity or alkalinity of a liquid medium. The membrane glass of the electrode supplies an electrochemical potential which is dependent upon the pH value of the medium. This potential is generated by the selective penetration of H + ions through the outer layer of the membrane. An electrochemical boundary layer with an electric potential forms at this point. An integrated Ag/AgCl reference system serves as the required reference electrode. The transmitter converts the measured voltage into the corresponding pH value using the Nernst equation.

Measuring system

A complete measuring system comprises:

  • pH electrode CPS71D or CPS71
  • Transmitter, e.g. Liquiline CM42, CM44x/R, Mycom S CPM153, Liquisys M CPM2x3
  • Memosens data cable CYK10 for Memosens sensors or CPK9 for analog sensors
  • Immersion, flow or retractable assembly, e.g. Cleanfit CPA871/875

Measuring principle

Glass electrode

Application

Hygienic and sterile applications, process

Characteristic

- resistant against reference poisoning - CIP/SIP and autoclavable - high accuracy - biocompatibility of the gel inside (EHEDG, 3A) - version upside-down installation available - pressurized reference (6 bar) available

Measurement range

pH 0-14

Measuring principle

- ceramic diaphragm - ion-trap

Design

- All shaft lengths with temperature sensor - Memosens - advanced gel technology

Material

glass / ceramic

Dimension

Diameter: 12mm (0.46inch)
Shaft lengths: 120, 225, 360 and 425 mm
(4.68, 8.77, 14.04 and 16,57 inch)

Process temperature

-15C ... 140C
(5F - 284F)

Process pressure

max. 13 bar
(188 psi)

Temperature sensor

optional with integrated Pt100 or Pt1000

Ex certification

Simple operational equipment, no certification necessary.

Connection

TOP68 connection head

Ingres protection

IP68

Additional certifications

3A, biocompatibility

Export Info
Made inGermany

  • ANALYSIS > MULTIPARAMETER TRANSMITTERS
    CM442-AAM1A1F010A-AA EH Liquiline CM442 1 or 2 channel digital multiparameter (pH, redox, ISFET, conductivity inductive and conductive, dissolved oxygen, nitrate and turbidity) transmitter. 2 Memosens inputs, Up to 4 current and 2 relay outputs. IP66+IP67. NEMA Type 4X enclos ..

  • ANALYSIS > MULTIPARAMETER TRANSMITTERS
    CM444-AAM20A0F010BAA-AA EH Liquiline CM444 4 channel digital multiparameter (pH, redox, ISFET, conductivity inductive and conductive, dissolved oxygen, nitrate and turbidity) transmitter. 4 Memosens inputs, up to 8 current and 4 relay outputs. Polycarbonate Housing. ..

  • ANALYSIS > MULTIPARAMETER TRANSMITTERS
    CM448-AA12A61AABAA-AA EH Liquiline CM448 8 channel digital multiparameter (pH, redox, ISFET, conductivity inductive and conductive, dissolved oxygen, nitrate and turbidity) transmitter. 8 Memosens inputs, up to 8 current and 2 relay outputs. IP67. Polycarbonate Housing. ..

  • PH & ORP ANALIZERS > ASSEMBLY
    CPA111-00A EH Dipfit CPA111 Universal Immersion assembly for the applications in open and closed tanks. DN100 flange connection. Accepts up to 3 pH and ORP sensors. ..

  • PH & ORP ANALIZERS > ASSEMBLY
    CPA140-231A110 EH Dipfit CPA140 immersion assembly for applications with aggressive media. Includes flange connection and holder with bayonet lock. Accepts up to 3 pH and ORP sensors. ..

  • PH & ORP ANALIZERS > ASSEMBLY
    CPA450-0B110 EH Cleanfit CPA450 Manual retractable assembly for water & wastewater, chemical, pulp & paper and power industries. Accepts 12mm DO, pH and ORP sensors. DN32 Process Connection. ..

  • PH & ORP ANALIZERS > ASSEMBLY
    CPA472D-A4A1C1D1 EH Cleanfit CPA472D Manual or automatic process retractable heavy-duty assembly for chemical and power industries. Accepts pH and ORP electrodes. DN50/80 Process Connection. ..

  • PH & ORP ANALIZERS > ASSEMBLY
    CPA473-A3A1A1A7 EH Cleanfit CPA473 Manual or automatic process retractable assembly with ball valve for chemical and industrial wastewater applications. Accepts pH and ORP electrodes. DN50/65 Process Connection. ..

  • PH & ORP ANALIZERS > ASSEMBLY
    CPA474-A3A1A1G7 EH Cleanfit CPA474 Manual or automatic process retractable assembly with ball valve for chemical and industrial wastewater applications. Accepts pH and ORP electrodes. DN50 Process Connection. ..

  • PH & ORP ANALIZERS > ASSEMBLY
    CPA871-AACA1ACB1C EH Cleanfit CPA871 Manual or automatic process retractable compact assembly for the water, wastewater and chemical industries. Suitable for vessels and pipes. Accepts standard 12mm pH and ORP sensors. NPT 1 1/2 or DN40/50/80 Process Connection. ..

  • PH & ORP ANALIZERS > ASSEMBLY
    CPA875-AAC1E1CA1A1A EH Cleanfit CPA875 Manual or automatic process retractable assembly for sterile and hygienic applications. Accepts standard (12mm) pH, ORP, oxygen and NIR sensors. DN25/50/65/100 Process Connection. ..

  • PH ANALIZERS > CABLES
    CYK10-A031 EH CYK10 Memosens Measuring Cable for Digital Sensors. IP68. FM, ATEX and CSA Approvals for Ex. ..


B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer, Check and Money Order

Checkout with Paypal

> PH ELECTRODES > GENERAL PURPOSE :    47 Items found.
CPS31-1AB2ESA
(378)

ENDRESS+HAUSER  CPS31-1AB2ESA

EH Ceratex CPS31 analog pH glass electrode for application in drinking water and swimming pools. 1 - 12 pH measurement range. Corrosion and moisture resistant. 60 psi max pressure. IP68.

CPS72-0PT2ESA
(390)

ENDRESS+HAUSER  CPS72-0PT2ESA

EH Ceragel CPS72 Analog ORP glass electrode for sterile and hygienic applications. Poison resistant. 230psi max pressure. IP68.

CPS31D-7AC21
(287)

ENDRESS+HAUSER  CPS31D-7AC21

EH Memosens CPS31D digital pH glass electrode for application in drinking water and swimming pools. Corrosion and moisture resistant. 60 psi max pressure. IP68.

CPS92-0PB2ESA
(288)

ENDRESS+HAUSER  CPS92-0PB2ESA

EH Orbipore CPS92 analog ORP glass electrode for highly turbid media. IP68. 189psi max pressure. Platinum measuring surface.

CPF201-C1A
(375)

ENDRESS+HAUSER  CPF201-C1A

EH Purisys CPF201 Analog pH glass electrode for pure and ultrapure water. 1-13 pH measurement range. 43.5psi max pressure. IP68.

CM72-AAADB1C1A1A1
(354)

ENDRESS+HAUSER  CM72-AAADB1C1A1A1

EH Liquiline CM72 1 channel small glass electrode transmitter for Memosens Sensors (ph, ORP, conductivity and oxygen). PEEK Housing. IP67 and IP68. 4-20ma Output. CSA Approval.

COS41-8S
(349)

ENDRESS+HAUSER  COS41-8S

EH Oxymax COS41 2-electrode amperometric sensor for the measurement of Dissolved Oxygen (O2) on water and wastewater applications. 0,05 - 20mg/l measuring range. Integrated NTC temperature sensor.

CCS50D-AA11BF
(350)

ENDRESS+HAUSER  CCS50D-AA11BF

EH Memosens CCS50D Digital Sensor for Amperometric measurement of dissolved Chlorine Dioxide (Cl2) in process and drinking water. 0-5 to 0-200 mg/l ClO2 range. Integrated 10k NTC temperature sensor.

CLD18-AGCP
(300)

ENDRESS+HAUSER  CLD18-AGCP

EH Smartec CLD18 toroidal system for inductive conductivity measurement in hygienic applications. Includes compact transmitter and Stainless steel Pt1000 temperature sensor. 200 S/cm - 1000 mS/cm measurement range. IP69.

CLS54D-AAMV5A2A
(301)

ENDRESS+HAUSER  CLS54D-AAMV5A2A

EH Indumax CLS54D Digital Memosens toroidal conductivity sensor for hygienic and sterile applications. Inductive cell. Corrosion and moisture resistant. DN50 Process Connection. PEEK material. Integrated Pt1000 temperature sensor. IP68.

CCS140-A
(171)

ENDRESS+HAUSER  CCS140-A

EH CCS140 analog free chlorine disinfection sensor for industrial and pool water treatment. Amperometric and membrane-covered. 0,05 - 20ppm free chlorine measurement range (pH 4 - 8,2). Optional NTC-temperature sensor. For installation in the CCA250 assembly.

CCS240-N
(329)

ENDRESS+HAUSER  CCS240-N

EH CCS240 Analog disinfection sensor for standard measurement of Chlorine Dioxide (Cl2) 0,05 - 20ppm. Amperometric and membrane-covered. NTC-temperature sensor.

CM82-AAXAB2C1A1A1
(355)

ENDRESS+HAUSER  CM82-AAXAB2C1A1A1

EH Liquiline CM82 1 channel small glass electrode transmitter for Memosens Sensors (ph, ORP, conductivity, oxygen and chlorine). Configurable multiparameter. PEEK Housing. IP67 and IP68. 4-20ma and HART Outputs. Optional Bluetooth. CSA Approval.

CCS120-AS0
(170)

ENDRESS+HAUSER  CCS120-AS0

EH CCS120 analog total chlorine (HOCl, OCl, chloramines) disinfection sensor for all water and wastewater applications. 0,1 - 10ppm total chlorine measurement range (pH 6,5 - 9,5). NPT 3/4" Thread. Includes NTC-temperature sensor and TOP68 plug-in head.



 
COS61-A0F0
(180)

ENDRESS+HAUSER  COS61-A0F0

EH Oxymax COS61 dissolved and optical sensor for the measurement of Oxygen (O2) in water, wastewater and utilities applications. High performance sensor: Fast and accurate. 0 to 400hPa measuring range. Stainless steel sensor body. G1" thread process connection. NTC temperature sensor included.

CYZ71D-AAB110
(273)

ENDRESS+HAUSER  CYZ71D-AAB110

EH Memobase Plus CYZ71D multichannel multiparameter software for liquid analysis with digital Memosens sensors. Includes USB cable, sensor connection box MemoLink and Memosens lab cable CYK20 optionally.

COS22-AA1A2B22
(177)

ENDRESS+HAUSER  COS22-AA1A2B22

EH Oxymax COS22 analog sensor for the measurement of Oxygen (O2) with long-term stability for frequent sterilizations and autoclavability. 0 to 400 hPa (0 to 6 psi) measuring range. Fluorelastomer FDA Process Sealing. Integrated temperature sensor.

CLD134-E00030AA1
(304)

ENDRESS+HAUSER  CLD134-E00030AA1

EH Smartec CLD134 toroidal system for inductive conductivity measurement in hygienic applications. Includes compact transmitter and Stainless steel Pt1000 temperature sensor. 100 S/cm - 2000 mS/cm measurement range. IP67.

COS61D-AAA1A2
(181)

ENDRESS+HAUSER  COS61D-AAA1A2

EH Oxymax COS61D digital memosens and optical sensor for measurement of Oxygen (O2) in water, wastewater and utilities applications. Fast and accurate sensor. 0 to 400hPa measuring range. Stainless steel sensor body. G1" thread process connection. NTC temperature sensor included.

CUE25-A
(319)

ENDRESS+HAUSER  CUE25-A

EH Turbimax CUE25 Handheld turbidity meter for on-site quality control. Infrared Measurement. 00.01-1100 NTU/FNU measurement range. ABS NEMA4X Housing. IP67.



 
Page: 1 | 2 | 3 | All