Process Control Instruments, Field Devices and Industrial Automation
ENDRESS+HAUSER CPS72-0PT2ESA (1)
  • Overview
  • Benefits
  • Specs
  • Related
  • Literature

EH Ceragel CPS72 Analog ORP glass electrode for sterile and hygienic applications. Poison resistant. 230psi max pressure. IP68.

Part# with Options:        CPS72-0PT2ESA
Price with Options:        Please Email us your request for quote   

Options:    

Shaft Length
(1) Shaft Length for EH CPS72
Head
(2) Head for EH CPS72

  Availability 2 Days  ]

For process technology, hygienic and sterile applications with poison-resistant reference with ion trap

Application
  • Hygienic and sterile applications (sterilizable, autoclavable)
    • Fermenters
    • Biotechnology
    • Pharmaceutical industry
    • Food industry
  • Process technology and monitoring of processes with:
    • Rapidly changing ORP measured values
    • High proportion of electrode poisons such as H 2 S

With ATEX, FM and CSA approval for use in hazardous areas

Your benefits
  • Certified biocompatibility, no cytotoxicity
  • Acrylamide-free bridging electrolyte
  • Integrated temperature sensor in the case of Memosens
  • Poison-resistant reference with ion trap, resulting in a very long service life
  • Bridging electrolyte free of silver ions
  • Suitable for CIP/SIP cleaning and autoclavable, depending on version up to 140 C (284 F)
Measuring principle ORP measurement

The oxidation-reduction potential is an indicator of the equilibrium between oxidizing and reducing substances in the medium. The oxidation-reduction potential is measured with a gold or platinum electrode instead of the pH-sensitive glass membrane. As in the case of pH measurement, an integrated Ag/AgCl reference system is used as the reference electrode.

Measuring system

A complete measuring system comprises:

  • ORP electrode CPS72 or CPS72D
  • Transmitter, e.g. Liquiline CM42 or Liquiline CM44x (for CPS72D with Memosens technology)
  • Special measuring cable. e.g. CPK9 or Memosens data cable CYK10 for CPS72D
  • Immersion, flow or retractable assembly, e.g. Cleanfit H CPA475

Measuring principle

Sensor ORP / Redox

Application

- Hygienic and sterile applications - pharmaceuticals, biotechnology, fermenters, contaminating media.

Characteristic

- Gel-compact-electrode with ceramic diaphragm - Platinum-cap - CIP/SIP and autoclavable - high accuracy

Measurement range

-1500 mV - +1500 mV

Measuring principle

- ceramic diaphragm - double chamber and double gel reference - platinum-ring

Material

Glass electrode with ceramic diaphragm and platinum ring.

Dimension

Diameter: 12 mm
Shaft lengths: 120, 225, 360 mm

Process temperature

-15C - 135C

Process pressure

max. 16bar

Ex certification

Simple operational device, no certification necessary.

Connection

TOP68 connection head

Ingres protection

IP68

Additional certifications

Biocompatibility acc. ISO 10993-5 and USP (current version).
TV certificate for pressure resistance up to 16 bar with triple overpressure safety.

Export Info
Made inGermany

  • ANALYSIS > MULTIPARAMETER TRANSMITTERS
    CM442-AAM1A1F010A-AA EH Liquiline CM442 1 or 2 channel digital multiparameter (pH, redox, ISFET, conductivity inductive and conductive, dissolved oxygen, nitrate and turbidity) transmitter. 2 Memosens inputs, Up to 4 current and 2 relay outputs. IP66+IP67. NEMA Type 4X enclos ..

  • ANALYSIS > MULTIPARAMETER TRANSMITTERS
    CM444-AAM20A0F010BAA-AA EH Liquiline CM444 4 channel digital multiparameter (pH, redox, ISFET, conductivity inductive and conductive, dissolved oxygen, nitrate and turbidity) transmitter. 4 Memosens inputs, up to 8 current and 4 relay outputs. Polycarbonate Housing. ..

  • ANALYSIS > MULTIPARAMETER TRANSMITTERS
    CM448-AA12A61AABAA-AA EH Liquiline CM448 8 channel digital multiparameter (pH, redox, ISFET, conductivity inductive and conductive, dissolved oxygen, nitrate and turbidity) transmitter. 8 Memosens inputs, up to 8 current and 2 relay outputs. IP67. Polycarbonate Housing. ..

  • ANALYSIS > TRANSMITTERS
    CM42-CAA000EAE00 EH Liquiline M CM42 Two-wire transmitter for Ex and non-Ex areas. One or two analog outputs. FOUNDATION Fieldbus, PROFIBUS PA and HART protocols. ATEX, FM, CSA, NEPSI and TIIS Approvals. ..

  • ORP ELECTRODES > HAZARDOUS LOCATIONS
    CPS72D-7PT2C EH Ceragel CPS72D Digital ORP Memosens glass electrode for sterile and hygienic applications. Poison resistant. 230psi max pressure. IP68. ATEX, FM and CSA approval. ..

  • PH & ORP ANALIZERS > ASSEMBLY
    CPA111-00A EH Dipfit CPA111 Universal Immersion assembly for the applications in open and closed tanks. DN100 flange connection. Accepts up to 3 pH and ORP sensors. ..

  • PH & ORP ANALIZERS > ASSEMBLY
    CPA250-A00 EH Flowfit CPA250 Universal Flow assembly for the water and wastewater industry. Pipe installation. Accepts up to 3 pH and ORP sensors. NPT 1 Process Connection. ..

  • PH & ORP ANALIZERS > ASSEMBLY
    CPA450-0B110 EH Cleanfit CPA450 Manual retractable assembly for water & wastewater, chemical, pulp & paper and power industries. Accepts 12mm DO, pH and ORP sensors. DN32 Process Connection. ..

  • PH & ORP ANALIZERS > ASSEMBLY
    CPA472D-A4A1C1D1 EH Cleanfit CPA472D Manual or automatic process retractable heavy-duty assembly for chemical and power industries. Accepts pH and ORP electrodes. DN50/80 Process Connection. ..

  • PH ANALIZERS > CABLES
    CPK9-NHA1A EH CPK9 Measuring Cable for Analog Sensors. IP68 ..

  • PH ANALIZERS > CABLES
    CYK10-A031 EH CYK10 Memosens Measuring Cable for Digital Sensors. IP68. FM, ATEX and CSA Approvals for Ex. ..

  • PH-ORP-OXYGEN ELECTRODES > ASSEMBLY
    CPA442-A1D1B11 EH Unifit CPA442 hygienic process assembly for food and beverage industries. Accepts 12mm Oxygen (O2), pH and ORP sensors. DN25 or DN50 Process Connection. ..


B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer, Check and Money Order

Checkout with Paypal

> GENERAL PURPOSE :    46 Items found.
CPS31-1AB2ESA
(378)

ENDRESS+HAUSER  CPS31-1AB2ESA

EH Ceratex CPS31 analog pH glass electrode for application in drinking water and swimming pools. 1 - 12 pH measurement range. Corrosion and moisture resistant. 60 psi max pressure. IP68.

CPS71-1TB2ESA
(389)

ENDRESS+HAUSER  CPS71-1TB2ESA

EH Ceragel CPS71 Analog pH glass electrode for sterile and hygienic applications. Poison resistant. 188psi max pressure. IP68.

CPS31D-7AC21
(287)

ENDRESS+HAUSER  CPS31D-7AC21

EH Memosens CPS31D digital pH glass electrode for application in drinking water and swimming pools. Corrosion and moisture resistant. 60 psi max pressure. IP68.

CPS92-0PB2ESA
(288)

ENDRESS+HAUSER  CPS92-0PB2ESA

EH Orbipore CPS92 analog ORP glass electrode for highly turbid media. IP68. 189psi max pressure. Platinum measuring surface.

CPF201-C1A
(375)

ENDRESS+HAUSER  CPF201-C1A

EH Purisys CPF201 Analog pH glass electrode for pure and ultrapure water. 1-13 pH measurement range. 43.5psi max pressure. IP68.

CM72-AAADB1C1A1A1
(354)

ENDRESS+HAUSER  CM72-AAADB1C1A1A1

EH Liquiline CM72 1 channel small glass electrode transmitter for Memosens Sensors (ph, ORP, conductivity and oxygen). PEEK Housing. IP67 and IP68. 4-20ma Output. CSA Approval.

COS41-8S
(349)

ENDRESS+HAUSER  COS41-8S

EH Oxymax COS41 2-electrode amperometric sensor for the measurement of Dissolved Oxygen (O2) on water and wastewater applications. 0,05 - 20mg/l measuring range. Integrated NTC temperature sensor.

CCS50D-AA11BF
(350)

ENDRESS+HAUSER  CCS50D-AA11BF

EH Memosens CCS50D Digital Sensor for Amperometric measurement of dissolved Chlorine Dioxide (Cl2) in process and drinking water. 0-5 to 0-200 mg/l ClO2 range. Integrated 10k NTC temperature sensor.

CLD18-AGCP
(300)

ENDRESS+HAUSER  CLD18-AGCP

EH Smartec CLD18 toroidal system for inductive conductivity measurement in hygienic applications. Includes compact transmitter and Stainless steel Pt1000 temperature sensor. 200 S/cm - 1000 mS/cm measurement range. IP69.

CLS54D-AAMV5A2A
(301)

ENDRESS+HAUSER  CLS54D-AAMV5A2A

EH Indumax CLS54D Digital Memosens toroidal conductivity sensor for hygienic and sterile applications. Inductive cell. Corrosion and moisture resistant. DN50 Process Connection. PEEK material. Integrated Pt1000 temperature sensor. IP68.

CCS140-A
(171)

ENDRESS+HAUSER  CCS140-A

EH CCS140 analog free chlorine disinfection sensor for industrial and pool water treatment. Amperometric and membrane-covered. 0,05 - 20ppm free chlorine measurement range (pH 4 - 8,2). Optional NTC-temperature sensor. For installation in the CCA250 assembly.

CCS240-N
(329)

ENDRESS+HAUSER  CCS240-N

EH CCS240 Analog disinfection sensor for standard measurement of Chlorine Dioxide (Cl2) 0,05 - 20ppm. Amperometric and membrane-covered. NTC-temperature sensor.

CM82-AAXAB2C1A1A1
(355)

ENDRESS+HAUSER  CM82-AAXAB2C1A1A1

EH Liquiline CM82 1 channel small glass electrode transmitter for Memosens Sensors (ph, ORP, conductivity, oxygen and chlorine). Configurable multiparameter. PEEK Housing. IP67 and IP68. 4-20ma and HART Outputs. Optional Bluetooth. CSA Approval.

CCS120-AS0
(170)

ENDRESS+HAUSER  CCS120-AS0

EH CCS120 analog total chlorine (HOCl, OCl, chloramines) disinfection sensor for all water and wastewater applications. 0,1 - 10ppm total chlorine measurement range (pH 6,5 - 9,5). NPT 3/4" Thread. Includes NTC-temperature sensor and TOP68 plug-in head.



 
COS61-A0F0
(180)

ENDRESS+HAUSER  COS61-A0F0

EH Oxymax COS61 dissolved and optical sensor for the measurement of Oxygen (O2) in water, wastewater and utilities applications. High performance sensor: Fast and accurate. 0 to 400hPa measuring range. Stainless steel sensor body. G1" thread process connection. NTC temperature sensor included.

CYZ71D-AAB110
(273)

ENDRESS+HAUSER  CYZ71D-AAB110

EH Memobase Plus CYZ71D multichannel multiparameter software for liquid analysis with digital Memosens sensors. Includes USB cable, sensor connection box MemoLink and Memosens lab cable CYK20 optionally.

COS22-AA1A2B22
(177)

ENDRESS+HAUSER  COS22-AA1A2B22

EH Oxymax COS22 analog sensor for the measurement of Oxygen (O2) with long-term stability for frequent sterilizations and autoclavability. 0 to 400 hPa (0 to 6 psi) measuring range. Fluorelastomer FDA Process Sealing. Integrated temperature sensor.

CLD134-E00030AA1
(304)

ENDRESS+HAUSER  CLD134-E00030AA1

EH Smartec CLD134 toroidal system for inductive conductivity measurement in hygienic applications. Includes compact transmitter and Stainless steel Pt1000 temperature sensor. 100 S/cm - 2000 mS/cm measurement range. IP67.

COS61D-AAA1A2
(181)

ENDRESS+HAUSER  COS61D-AAA1A2

EH Oxymax COS61D digital memosens and optical sensor for measurement of Oxygen (O2) in water, wastewater and utilities applications. Fast and accurate sensor. 0 to 400hPa measuring range. Stainless steel sensor body. G1" thread process connection. NTC temperature sensor included.

CUE25-A
(319)

ENDRESS+HAUSER  CUE25-A

EH Turbimax CUE25 Handheld turbidity meter for on-site quality control. Infrared Measurement. 00.01-1100 NTU/FNU measurement range. ABS NEMA4X Housing. IP67.



 
Page: 1 | 2 | 3 | All