EH CYA680 flow assembly for pH and conductivity measurement in pipelines of hygienic and sterile applications. Glass electrode measuring principle. Pipe mounting. 0,25" to 2" Clamp Connection.

Part# with Options:        CYA680-1A1C1
Price with Options:        Please Email us your request for quote   

Options:    

Sensor Connection & Length
(1) Sensor Connection & Length for EH CYA680
Material
(2) Material for EH CYA680
Nominal Diameter
(3) Nominal Diameter EH CYA680
Sealing Material
(4) Sealing Material EH CYA680

  Availability 10 Days  ]

Flow Assembly for the Life Sciences and Chemical Industry

Application
  • For 12 mm sensors with Pg 13.5
  • Installations with small pipe diameters
  • Hygienic and sterile applications
  • Chromatography
  • Filtrations
  • Reverse osmosis
Your benefits
  • Maximum product yield thanks to fast measured values in the smallest of sample volumes
  • High level of product safety: Flow assembly is perfectly suitable for CIP and SIP.
  • The PVDF-version is resistant to aggressive and corrosive media
  • Complies with the requirements of the Life Sciences industry: Certified biocompatibility in relation to biological reactivity in accordance with USP <87> and USP <88>, FDA-listed seals and hygienic, electropolished surfaces (Ra ≤ 0.38 μm)
Measuring system

A complete measuring system comprises:

  • Transmitter, for example Liquiline CM44P
  • One or two 12 mm sensors, e.g. CLS82D and / or CPS71D
  • Flow assembly CYA680
  • Measuring cable, for example CYK10

Measuring principle

UV photometric

Measuring principle

Glass electrode

Application

Life Sciences, Food&Beverages, Oil&Gas,

Installation

flow assembly,with Clamp 0,25" ... 2"

Characteristic

pipe mounting

Design

flow assembly with small bore from 5mm ... 45mm

Material

Holder: stainless steel or PVDF
Sealings: EPDM,

Dimension

flange spacing 82,55 mm, 3;25"

Process temperature

max.130C
266F

Process pressure

Stainless steel: max. 16 bar; PVDF: max 4 bar

Connection

Clamp 0,25" ... 2"

Additional certifications

Material certification 3.1 EN 10204
Surface

Export Info
Made inUnited States

  • ANALYSIS > MULTIPARAMETER TRANSMITTERS
    CM44P-AADINP1M00A0F015BAEA EH Liquiline CM44P 4 channel multiparameter (pH, redox, ISFET, conductivity inductive and conductive, dissolved oxygen, nitrate and turbidity) transmitter for up to 2 process photometers and 4 Memosens sensors. MIR Spectroscopy measuring principle. 0 to 2 ..

  • ORP ELECTRODES > HAZARDOUS LOCATIONS
    CPS12-0NA2ESA EH Orbisint CPS12 Analog ORP glass electrode sensor for standard applications in process and environmental technology. PTFE diaphragm. -1500 mV to +1500 mV measurement range. 230 psi max pressure. IP68. ATEX, FM and CSA approvals. ..

  • ORP ELECTRODES > HAZARDOUS LOCATIONS
    CPS12D-7NA2C EH Orbisint CPS12D Digital ORP glass electrode Memosens sensor for standard applications in process and environmental technology. Teflon diaphragm. -1500 mV to +1500 mV measurement range. 16bar max pressure. Pt1000 Temperature sensor. IP68. ATEX, FM and C ..

  • PH & ORP ELECTRODES > HAZARDOUS LOCATIONS
    CPS16D-7AT2C EH Memosens CPS16D digital combined pH and ORP glass electrode for standard applications in process technology and environmental engineering. PTFE diaphragm. Corrosion and moisture resistant. 230 psi max pressure. IP68. ATEX, IEC, FM and CSA approvals. ..

  • PH & ORP ELECTRODES > HAZARDOUS LOCATIONS
    CPS76D-7BB21 EH Memosens CPS76D Digital pH and ORP Memosens glass electrode for hygienic and sterile applications. Corrosion, moisture and poison resistant. 188psi max pressure. IP68. ATEX, IECEx, FM and CSA approvals. ..

  • PH ANALIZERS > CABLES
    CYK10-A031 EH CYK10 Memosens Measuring Cable for Digital Sensors. IP68. FM, ATEX and CSA Approvals for Ex. ..

  • PH ELECTRODES > FM
    CPS11-1AA2ESA EH Orbisint CPS11 pH Analog Electrode for measurement in process and environmental applications. PTFE diaphragm. Low maintenance and a long operating life. ATEX, IECEx, FM (Class I Div. 2), and CSA approval for use in hazardous areas. ..

  • PH ELECTRODES > FM
    CPS11D-7AA2C EH Orbisint CPS11D pH Digital Electrode with digital Memosens technology for measurement in process and environmental applications. PTFE diaphragm. Low maintenance and a long operating life. ATEX, IECEx, FM (Class I Div. 2), and CSA approval for use in ha ..

  • PH ELECTRODES > GENERAL PURPOSE
    CPS31D-7AC21 EH Memosens CPS31D digital pH glass electrode for application in drinking water and swimming pools. Corrosion and moisture resistant. 60 psi max pressure. IP68. ..

  • PH ELECTRODES > HAZARDOUS LOCATIONS
    CPS441-2ESC1 EH Tophit CPS441 analog pH sensor with ISFET electrode for measurement in blocking media. Up to 145psi max pressure. IP68. ATEX, FM and CSA approvals. ..

  • PH ELECTRODES > HAZARDOUS LOCATIONS
    CPS441D-72B1C EH Tophit CPS441D Digital pH sensor with Memosens ISFET electrode for measurement in blocking media. Up to 145psi max pressure. IP68. ATEX, FM and CSA approvals. ..


B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer, Check and Money Order

Checkout with Paypal

> PH & CONDUCTIVITY ANALIZERS > ASSEMBLY :    31 Items found.
CYH112-AA11A11A1
(365)

ENDRESS+HAUSER  CYH112-AA11A11A1

EH Flexdip CYH112 Modular holder system for water and wastewater sensors and assemblies. Up to 6 bar pressure. Works for floor, wall or rail fixings. UV photometric measuring principle.

CPA640-G311
(129)

ENDRESS+HAUSER  CPA640-G311

EH Ecofit CPA640 Universal compact assembly for installation of 120 mm water management sensors. PVDF or stainless steel 316L. Up to 10 bar pressure. NPT 1/2, 3/4" & 1" Process Connection.

CYA112-AA11A1AA
(364)

ENDRESS+HAUSER  CYA112-AA11A1AA

EH Flexdip CYA112 Immersion Modular assembly for water and wastewater. UV photometric measuring principle. Stainless steel or PVC versions.

CCA151-AAB1
(367)

ENDRESS+HAUSER  CCA151-AAB1

EH Flowfit CCA151 Flow assembly for disinfection measurement in drinking and process water with chlorine dioxide sensors. Plexiglas Housing. Panel, wall or pipe mounting.

CPA842-AA1E1AAA1
(374)

ENDRESS+HAUSER  CPA842-AA1E1AAA1

EH Unifit CPA842 hygienic process assembly for food and beverage industries. Accepts 12mm pH, ORP, Oxygen (O2), conductivity or cell growth sensors. DN25 or DN50 Process Connection.

CPA442-A1D1B11
(373)

ENDRESS+HAUSER  CPA442-A1D1B11

EH Unifit CPA442 hygienic process assembly for food and beverage industries. Accepts 12mm Oxygen (O2), pH and ORP sensors. DN25 or DN50 Process Connection.

COA250-A
(311)

ENDRESS+HAUSER  COA250-A

EH Cleanfit COA250 flow assembly for Dissolved Oxygen sensors. Wall mounting or unsupported installation in pipes. PVC Material. 871 psi max pressure.

CUA250-B
(184)

ENDRESS+HAUSER  CUA250-B

EH Flowfit CUA250 Turbidity assembly for water and wastewater applications in CUS31/CUS41/CUS51D turbidity sensors. PVC holder body. DN20 or DN50 process connection. Up to 6 bar process pressure.

CCA250-A0
(173)

ENDRESS+HAUSER  CCA250-A0

EH Flowfit CCA250 Flow assembly for free chlorine measurement in drinking, industrial and pool water. Designed to accommodate chlorine, pH and ORP sensors. Plexiglas Housing.

CPA250-A00
(285)

ENDRESS+HAUSER  CPA250-A00

EH Flowfit CPA250 Universal Flow assembly for the water and wastewater industry. Pipe installation. Accepts up to 3 pH and ORP sensors. NPT 1 Process Connection.

CUA120-A
(183)

ENDRESS+HAUSER  CUA120-A

EH CUA 120 Flange Adapter for mounting of CUS turbidity sensors. PVC or Stainless Steel Material. For mounting on weld-on flange. Up to 6 bar process pressure.

CPA111-00A
(284)

ENDRESS+HAUSER  CPA111-00A

EH Dipfit CPA111 Universal Immersion assembly for the applications in open and closed tanks. DN100 flange connection. Accepts up to 3 pH and ORP sensors.

CPA510-0110
(282)

ENDRESS+HAUSER  CPA510-0110

EH DipFit CPA510 immersion assembly for DN50 adapters. Includes bayonet lock-mounted electrode holder. Accepts pH and ORP sensors.

CLA111-00A
(306)

ENDRESS+HAUSER  CLA111-00A

EH Dipfit CLA111 immersion assembly for conductivity sensors in open and closed vessels. Includes DN100 flange connection and bayonet lock.

CPA240-23AA110
(286)

ENDRESS+HAUSER  CPA240-23AA110

EH Flowfit CPA240 Durable Flow assembly for all applications with high temperatures and pressures. Pipe installation. Accepts up to 3 pH and ORP sensors. DN25 or NPT 1/2 Process Connection.

CUA252-AAB111
(393)

ENDRESS+HAUSER  CUA252-AAB111

EH Flowfit CUA252 Turbidity assembly for drinking and process water applications with CUS52D turbidity sensor. Polyethylene holder body. G 1 1/4 process connection. Up to 6 bar process pressure.

CLA140-3A1A110
(305)

ENDRESS+HAUSER  CLA140-3A1A110

EH Dipfit CLA140 immersion assembly for conductivity sensors in applications with aggressive media. Includes flange connection and holder with bayonet lock. Thread G3/4 sensor connection. IP65.

CPA140-231A110
(283)

ENDRESS+HAUSER  CPA140-231A110

EH Dipfit CPA140 immersion assembly for applications with aggressive media. Includes flange connection and holder with bayonet lock. Accepts up to 3 pH and ORP sensors.

CYA251-AAA2A111
(396)

ENDRESS+HAUSER  CYA251-AAA2A111

EH Flowfit CYA251 flow assembly for nitrate/SAC, turbidity and oxygen in water and wastewater. UV photometric measuring principle. PVC Material.

CUA262-AAA121
(394)

ENDRESS+HAUSER  CUA262-AAA121

EH Flowfit CUA262 Turbidity assembly for drinking and process water applications with CUS52D turbidity sensor. Stainless steel holder body. Up to 6 bar process pressure.



 
Page: 1 | 2 | All