EH Proline Promag P 300 Electromagnetic Flowmeter for highest medium temperatures with compact transmitter. 4 dm3/min to 9600 m3/h measuring range. DN 15 Nominal Diameter. IP66/IP67. Aluminum (AlSi10Mg) housing. PTFE Liner. Includes display, 4-20ma, switch, double pulse and relay outputs. Optional Modbus RS485 communication. ATEX, IECEx, cCSAus and INMETRO approvals.

Part# with Options:        5P3B15-AAIBAAAAAAEA1KGAA1
Price with Options:        Please Email us your request for quote   

Options:    

Approval: Transmitter & Sensor
(1) Approval: Transmitter & Sensor for EH Promag P300
Power Supply
(2) Power Supply for EH Promag F300/P300
Output
(3) Output for EH Promag P300
Output 2 & 3
(4) Output 2 & 3 for EH Promag P300/W300
Output 2 & 3
(5) Output 2 & 3 for EH Promag P300/W300
Display & Operation
(6) Display & Operation for EH Promag P300
Electrical Connection
(7) Electrical Connection for EH Promag P300/W300
Process Connection
(8) Process Connection for EH Promag P300
Electrodes
(9) Electrodes for EH Promag P300
Calibration Flow
(10) Calibration Flow for EH Promag P300

  Availability 2 Weeks  ]

The flowmeter for highest medium temperatures with a compact, easily accessible transmitter

Application
  • The bidirectional measuring principle is virtually independent of pressure, density, temperature and viscosity
  • Dedicated to chemical and process applications with corrosive liquids and high medium temperatures
Device properties
  • Nominal diameter: max. DN 600 (24")
  • All common Ex approvals
  • Liner made of PTFE or PFA
  • Compact dual-compartment housing with up to 3 I/Os
  • Backlit display with touch control and WLAN access
  • Remote display available
Your benefits
  • Versatile applications wide variety of wetted materials
  • Energy-saving flow measurement no pressure loss due to cross-section constriction
  • Maintenance-free no moving parts
  • Full access to process and diagnostic information numerous, freely combinable I/Os and fieldbuses
  • Reduced complexity and variety freely configurable I/O functionality
  • Integrated verification Heartbeat Technology
Measuring principle

Following Faraday's law of magnetic induction, a voltage is induced in a conductor moving through a magnetic field.

In the electromagnetic measuring principle, the flowing medium is the moving conductor. The voltage induced (U e ) is proportional to the flow velocity (v) and is supplied to the amplifier by means of two measuring electrodes. The flow volume (Q) is calculated via the pipe cross-section (A). The DC magnetic field is created through a switched direct current of alternating polarity.

Measuring system

The device consists of a transmitter and a sensor.

The device is available as a compact version:
The transmitter and sensor form a mechanical unit.

Measuring principle

Electromagnetic

Product headline

High-temperature flowmeter for process applications with a compact, easily accessible transmitter. Dedicated to chemical and process applications with corrosive liquids and high medium temperatures.

Sensor features

Diverse applications wide variety of wetted materials. Energy-saving flow measurement no pressure loss due to cross-section constriction. Maintenance-free no moving parts. Nominal diameter: max. DN 600 (24"). All common Ex approvals.

Transmitter features

Full access to process and diagnostic information numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety freely configurable I/O functionality. Integrated verification Heartbeat Technology. Compact dual-compartment housing with up to 3 I/Os. Backlit display with touch control and WLAN access.

Nominal diameter range

DN 15 to 600 ( to 24")

Wetted materials

Liner: PFA; PTFE
Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022); Tantalum; Platinum; Titanium; Duplex 1.4462 (UNS S31803)

Measured variables

Volume flow, conductivity, mass flow

Max. measurement error

Volume flow (standard): 0.5 % o.r. 1 mm/s (0.04 in/s)
Volume flow (option): 0.2 % o.r. 2 mm/s (0.08 in/s)

Measuring range

4 dm/min to 9600 m/h (1 gal/min to 44 000 gal/min)

Max. process pressure

PN 40, Class 300, 20K

Medium temperature range

Liner material PFA: 20 to +150 C (4 to +302 F)
Liner material PFA high-temperature: 20 to +180 C (4 to +356 F)
Liner material PTFE: 40 to +130 C (40 to +266 F)

Ambient temperature range

Flange material carbon steel: 10 to +60 C (+14 to +140 F)
Flange material stainless steel: 40 to +60 C (40 to +140 F)

Sensor housing material

DN 15 to 300 ( to 12""): AlSi10Mg, coated
DN 350 to 600 (14 to 24""): Carbon steel with protective varnish

Transmitter housing material

AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L; stainless steel for hygenic transmitter design

Degree of protection

Standard: IP66/67, Type 4X enclosure
Option: IP69

Display/Operation

4-line backlit display with touch control (operation from outside)
Configuration via local display and operating tools possible
Remote display available

Outputs

3 outputs:
4-20 mA HART (active/passive)
4-20 mA WirelessHART
4-20 mA (active/passive)
Pulse/frequency/switch output (active/passive)
Double pulse output (active/passive)
Relay output

Inputs

Status input
4-20 mA input

Digital communication

HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, Profinet, Ethernet/IP, OPC-UA

Power supply

DC 24 V
AC 100 to 230 V
AC 100 to 230 V / DC 24 V (non-hazardous area)

Hazardous area approvals

ATEX, IECEx, cCSAus, INMETRO, NEPSI, EAC

Product safety

CE, C-tick, EAC marking

Functional safety

Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511

Metrological approvals and certificates

Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
Heartbeat Technology complies with the requirements for traceable verification according to ISO 9001:2008 Section 7.6 a (TV-attestation)

Pressure approvals and certificates

PED, CRN

Material certificates

3.1 material

Hygienic approvals and certificates

ACS, NSF 61

Export Info
Made inFrance
Harmonized Tariff Code (HTC)9026107000


B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer, Check and Money Order

Checkout with Paypal

> HAZARDOUS LOCATIONS :    18 Items found.
6BABL1-AADAAAASAGA1G
(144)

ENDRESS+HAUSER  6BABL1-AADAAAASAGA1G

EH Proline t-mass B 150 Thermal Mass Flowmeter for measurement on large pipelines or rectangular ventilation ducts. 20 to 720 000 kg/h measuring range. DN80 Nominal Diameter. 18-30VDC. Aluminum (AlSi10Mg) housing. IP66/IP67. Includes 4-20ma and switch outputs and 4-line backlit display with push buttons. ATEX, IECEx and 0cCSAus approvals.

DTI200-A16A1A
(148)

ENDRESS+HAUSER  DTI200-A16A1A

EH Magphant Electromagnetic compact Flowmeter and Limit Switch for repeatable flow monitoring. 0...56'550 m3/h measuring range. DN15 to DN2000 Nominal Diameter. IP66 NEMA 4X Enclosure. Includes 4-20mA and relay outputs. FM and CSA approvals.

5H1B02-AADBAAA00000A
(139)

ENDRESS+HAUSER  5H1B02-AADBAAA00000A

EH Proline Promag H 100 Electromagnetic Flowmeter for the smallest flow rates with ultra compact transmitter. 0.06 dm3/min to 600 m3/h measuring range. DN 2 Nominal Diameter. IP66/IP67. Aluminum (AlSi10Mg) housing. 24 VDC. Includes 4-20ma and switch outputs. Optional 4 line backlit display and Modbus RS485 communication. ATEX, IECEx, cCSAus, INMETRO and EAC approvals.

5H3B02-AAIBAAAAAA00000AA1
(415)

ENDRESS+HAUSER  5H3B02-AAIBAAAAAA00000AA1

EH Proline Promag H 300 Electromagnetic Flowmeter with compact transmitter for hygienic applications. 0.06 dm/min to 600 m/h measuring range. DN 02 Nominal Diameter. IP66/IP67. Aluminum (AlSi10Mg) or stainless steel housing. Includes 4-20ma, pulse/frequency/switch and double pulse outputs. ATEX, IECEx, cCSAus and INMETRO approvals.

7F2C15-AAAACAAAAAAAASKA1
(143)

ENDRESS+HAUSER  7F2C15-AAAACAAAAAAAASKA1

EH Proline Prowirl F 200 Vortex Flowmeter with wet steam detection for heavy duty applications. Compact or remote version. 0.16 to 2412 m3/h measuring range. DN15 Nominal Diameter. Aluminum (AlSi10Mg) housing. IP66/IP67. Includes 4-20ma and switch outputs and 4-line backlit display. ATEX, IECEx and cCSAus approvals.

5H2B15-AAAACA00000A
(414)

ENDRESS+HAUSER  5H2B15-AAAACA00000A

EH Proline Promag H 200 Electromagnetic Flowmeter with loop-powered technology for smallest flow rates. 0.06 dm/min to 300 m/h measuring range. DN 15 Nominal Diameter. IP66/IP67. Aluminum (AlSi10Mg) housing. Includes 4-20ma and pulse/frequency/switch outputs. ATEX, IECEx, cCSAus and INMETRO approvals.

5E1B80-AADBAAA8A1KGA
(413)

ENDRESS+HAUSER  5E1B80-AADBAAA8A1KGA

EH Proline Promag E 100 Electromagnetic Flowmeter with ultra-compact transmitter. 4 dm/min to 9600 m/h measuring range. DN 80 Nominal Diameter. 24VDC. IP66. Aluminum (AlSi10Mg) housing. Includes 4-20ma and pulse/frequency/switch outputs. Optional Modbus RS485 communication. ATEX, IECEx, cCSAus and INMETRO approvals.

5W3B25-AAEIBAAAAAAUA1KGAA1
(409)

ENDRESS+HAUSER  5W3B25-AAEIBAAAAAAUA1KGAA1

EH Proline Promag W 300 Electromagnetic Flowmeter with compact transmitter for water and wastewater applications. 9 dm/min to 162 000 m/h measuring range. DN 25 Nominal Diameter. IP66/IP67. Aluminum (AlSi10Mg) housing. Includes 4-20ma, switch, double pulse and relay outputs. Optional Modbus RS485 communication. ATEX and cCSAus approvals.

5H5B15-AAIBAAAAFAAAAA00000AA1
(416)

ENDRESS+HAUSER  5H5B15-AAIBAAAAFAAAAA00000AA1

EH Proline Promag H 500 Electromagnetic Flowmeter for hygienic applications as remote version with up to 4 I/Os. 0.06 dm/min to 600 m/h measuring range. DN 15 (1/2") Nominal Diameter. IP66/IP67. Aluminum (AlSi10Mg) housing. Includes 4-20ma, pulse/frequency/switch and relay outputs. ATEX, IECEx, cCSAus and INMETRO approvals.

5P1B15-AADBAAAEA1KGA
(138)

ENDRESS+HAUSER  5P1B15-AADBAAAEA1KGA

EH Proline Promag P 100 Electromagnetic Flowmeter for highest medium temperatures with ultra-compact transmitter. 4 dm3/min to 9600 m3/h measuring range. DN 15 Nominal Diameter. IP66/IP67. Aluminum (AlSi10Mg) housing. 24VDC. PTFE Liner. Includes display, 4-20ma and switch outputs. Optional Modbus RS485 communication. ATEX, IECEx, cCSAus and INMETRO approvals.

9B2B80-AAAACA1W0W1
(141)

ENDRESS+HAUSER  9B2B80-AAAACA1W0W1

EH Proline Prosonic Flow B 200 Ultrasonic Flowmeter for biogas measurement with loop-powered technology. 1 to 30 m/s measuring range. DN 80 Nominal Diameter. IP66/IP67. Aluminum (AlSi10Mg) housing. Includes 4-20ma and switch outputs. Optional 4-line backlit display. ATEX, IECEx, cCSAus, NEPSI and INMETRO approvals.

8FE08-AAASAABAA10N
(147)

ENDRESS+HAUSER  8FE08-AAASAABAA10N

EH LPGmass Coriolis Flowmeter for measurement of LPG. 0 to 45000 kg/h measuring range. DN8 Nominal Diameter. Aluminum housing. IP67 type 4X Enclosure. 10-30VDC, 20-28VAC. Includes switch outputs and Modbus RS485 communication. ATEX, IECEx, NEC/CEC, FM, CSA, NEPSI and UL approvals.

8FF08-AG15AABAA10N
(145)

ENDRESS+HAUSER  8FF08-AG15AABAA10N

EH CNGmass Coriolis Flowmeter with the highest accuracy. 0 to 150 kg/min measuring range. DN8 Nominal Diameter. G1/2" female thread. Aluminum housing. IP67 type 4X Enclosure. Includes switch outputs and Modbus RS485 communication. ATEX, IECEx, NEC/CEC, FM, CSA, NEPSI and UL approvals.

8F1B08-AADBAAASAAASA
(140)

ENDRESS+HAUSER  8F1B08-AADBAAASAAASA

EH Proline Promass F 100 Coriolis Flowmeter with premium accuracy, robustness and ultra-compact transmitter. 0 to 2200000 kg/h measuring range. DN 8 Nominal Diameter. IP66/IP67. Aluminum (AlSi10Mg) housing. Includes 4-20ma and switch outputs. Optional 4-line backlit display and Modbus RS485 communication. ATEX, cCSAus and IECEx approvals.

8P1B15-AADBAAABBAAWA
(411)

ENDRESS+HAUSER  8P1B15-AADBAAABBAAWA

EH Proline Promass P 100 Coriolis Flowmeter with ultra-compact transmitter for applications in sterile environments. 0 to 70000 kg/h measuring range. DN 08 Nominal Diameter. 24VDC. IP66/IP67. Aluminum (AlSi10Mg) housing. Includes 4-20ma, switch, pulse and frequency outputs. Optional Modbus RS485 communication. ATEX, IECEx, cCSAus and INMETRO approvals.

83E50-AAASAAAAAAAA
(189)

ENDRESS+HAUSER  83E50-AAASAAAAAAAA

EH Proline Promass 83E Coriolis flowmeter with extended transmitter functionality for highly accurate measurement of liquids and gases. 0 to 180000 kg/h measuring range. DN 50 Nominal Diameter. IP67 type 4X Enclosure. Includes 0-20 mA, 4-20 mA, switch and relay outputs. Touch control and four line display. ATEX, IECEx, FM and CSA approvals.

8F3B25-AAIBAAAAAASAAASAA1
(408)

ENDRESS+HAUSER  8F3B25-AAIBAAAAAASAAASAA1

EH Proline Promass F 300 Coriolis Flowmeter with highly accurate sensor and robust compact transmitter. 0 to 2 200000 kg/h measuring range. DN 25 Nominal Diameter. IP66/IP67. Aluminum (AlSi10Mg) housing. Includes display, 4-20ma, switch, double pulse and relay outputs. Optional Modbus RS485 communication. ATEX, IECEx, cCSAus and INMETRO approvals.

8DF08-AG15AAAAA70M
(146)

ENDRESS+HAUSER  8DF08-AG15AAAAA70M

EH CNGmass DCI Coriolis Flowmeter. 0 to 150 kg/min measuring range. DN8 Nominal Diameter. G1/2" female thread. Aluminum housing. IP67 type 4X Enclosure. Includes 0-20mA, 4-20mA and switch outputs and Modbus RS485 communication. ATEX, IECEx and NEC/CEC approvals.