Process Control Instruments, Field Devices and Industrial Automation
ENDRESS+HAUSER 5W3B25-AAEIBAAAAAAUA1KGAA1 (1)
  • Overview
  • Benefits
  • Specs
  • Literature

EH Proline Promag W 300 Electromagnetic Flowmeter with compact transmitter for water and wastewater applications. 9 dm/min to 162 000 m/h measuring range. DN 25 Nominal Diameter. IP66/IP67. Aluminum (AlSi10Mg) housing. Includes 4-20ma, switch, double pulse and relay outputs. Optional Modbus RS485 communication. ATEX and cCSAus approvals.

Part# with Options:        5W3B25-AAEIBAAAAAAUA1KGAA1
Price with Options:        Please Email us your request for quote   

Options:    

Approval: Transmitter & Sensor
(1) Approval: Transmitter & Sensor for EH Promag W300
Design
(2) Design for EH Promag W300
Power Supply
(3) Power Supply for EH Promag F300/P300
Output
(4) Output for EH Promag W300
Output 2 & 3
(5) Output 2 & 3 for EH Promag P300/W300
Output 2 & 3
(6) Output 2 & 3 for EH Promag P300/W300
Display & Operation
(7) Display & Operation for EH Promag W300
Electrical Connection
(8) Electrical Connection for EH Promag P300/W300
Liner
(9) Liner for EH Promag W300
Process Connection
(10) Process Connection for EH Promag W300
Electrodes
(11) Electrodes for EH Promag W300
Calibration Flow
(12) Calibration Flow for EH Promag W300

  Availability 2 Weeks  ]

The specialist for demanding water and wastewater applications with compact, easily accessible transmitter

Application
  • The bidirectional measuring principle is virtually independent of pressure, density, temperature and viscosity
  • Dedicated to the measurement of industrial or municipal water and wastewate
Device properties
  • International drinking water approvals
  • Compact dual-compartment housing with up to 3 I/Os
  • Backlit display with touch control and WLAN access
  • Remote display available
Your benefits
  • Flexible engineering sensor with welded or lap-joint process connections
  • Reliable measurement accurate measured values even with 0 DN inlet run
  • Improved plant availability sensor compliant with industryspecific requirements
  • Full access to process and diagnostic information numerous, freely combinable I/Os and fieldbuses
  • Reduced complexity and variety freely configurable I/O functionality
  • Integrated verification Heartbeat Technology
Measuring principle

Following Faraday's law of magnetic induction, a voltage is induced in a conductor moving through a magnetic field.

Ue: Induced voltage
B: Magnetic induction (magnetic field)
L: Electrode spacing
I: Current
v: Flow velocity

In the electromagnetic measuring principle, the flowing medium is the moving conductor. The voltage induced (U e ) is proportional to the flow velocity (v) and is supplied to the amplifier by means of two measuring electrodes. The flow volume (Q) is calculated via the pipe cross-section (A). The DC magnetic field is created through a switched direct current of alternating polarity.

Formulae for calculation
  • Induced voltage Ue = B L v
  • Volume flow Q = A v
Measuring system

The device consists of a transmitter and a sensor.

The device is available as a compact version:
The transmitter and sensor form a mechanical unit.

Measuring principle

Electromagnetic

Product headline

Specialist for demanding water and wastewater applications with a compact, easily accessible transmitter. Dedicated to the measurement of industrial or municipal water and wastewater.

Sensor features

Flexible engineering sensor with welded or lap-joint process connections. Reliable measurement accurate measured values even with 0 DN inlet run. Improved plant availability sensor compliant with industry-specific requirements. International drinking water approvals. .

Transmitter features

Full access to process and diagnostic information numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety freely configurable I/O functionality. Integrated verification Heartbeat Technology. Compact dual-compartment housing with up to 3 I/Os. Backlit display with touch control and WLAN access.

Nominal diameter range

DN 25 to 2400(1 to 90")

Wetted materials

Liner: Polyurethane; Hard rubber, PTFE
Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022); Tantalum

Measured variables

Volume flow, conductivity, mass flow

Max. measurement error

Volume flow (standard): 0.5 % o.r. 1 mm/s (0.04 in/s)
Volume flow (option): 0.2 % o.r. 2 mm/s (0.08 in/s), Flat Spec

Measuring range

9 dm/min to 162 000 m/h (2.5 gal/min to 100 000 gal/min)

Max. process pressure

PN 40, Class 300, 20K

Medium temperature range

Liner material hard rubber: 0 to +80 C (+32 to +176 F)
Liner material polyurethane: 20 to +50 C (4 to +122 F)
Liner material PTFE: 20 to +90 C (4 to +194 F)

Ambient temperature range

Flange material carbon steel: 10 to +60 C (+14 to +140 F)
Flange material stainless steel: 40 to +60 C (40 to +140 F)

Sensor housing material

DN 25 to 300 (1 to 12"): AlSi10Mg, coated
DN 25 to 2400 (1 to 90"): Carbon steel with protective varnish
Sensor connection housing (standard): AlSi10Mg, coated
Sensor connection housing (option): Polycarbonate; 1.4409 (CF3M) similar to 316L

Transmitter housing material

AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L; stainless steel for hygenic transmitter design

Display/Operation

4-line backlit display with touch control (operation from outside)
Configuration via local display and operating tools possible
Remote display available

Outputs

3 outputs:
4-20 mA HART (active/passive)
4-20 mA WirelessHART
4-20 mA (active/passive)
Pulse/frequency/switch output (active/passive)
Double pulse output (active/passive)
Relay output

Inputs

Status input 4-20 mA input

Digital communication

HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, Profinet, Ethernet/IP, OPC-UA

Power supply

DC 24 V
AC 100 to 230 V
AC 100 to 230 V / DC 24 V (non-hazardous area)

Product safety

CE, C-tick, EAC marking

Functional safety

Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511

Metrological approvals and certificates

Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR
Heartbeat Technology complies with the requirements for traceable verification according to ISO 9001:2008 Section 7.6 a (TV-attestation)

Pressure approvals and certificates

CRN, PED

Material certificates

3.1 material

Hygienic approvals and certificates

ACS, KTW/W270, NSF 61, WRAS BS 6920

Export Info
Made inFrance
Harmonized Tariff Code (HTC)9026107000


B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer, Check and Money Order

Checkout with Paypal

> ELECTROMAGNETIC TRANSMITTERS > HAZARDOUS LOCATIONS :    18 Items found.
6BABL1-AADAAAASAGA1G
(144)

ENDRESS+HAUSER  6BABL1-AADAAAASAGA1G

EH Proline t-mass B 150 Thermal Mass Flowmeter for measurement on large pipelines or rectangular ventilation ducts. 20 to 720 000 kg/h measuring range. DN80 Nominal Diameter. 18-30VDC. Aluminum (AlSi10Mg) housing. IP66/IP67. Includes 4-20ma and switch outputs and 4-line backlit display with push buttons. ATEX, IECEx and 0cCSAus approvals.

DTI200-A16A1A
(148)

ENDRESS+HAUSER  DTI200-A16A1A

EH Magphant Electromagnetic compact Flowmeter and Limit Switch for repeatable flow monitoring. 0...56'550 m3/h measuring range. DN15 to DN2000 Nominal Diameter. IP66 NEMA 4X Enclosure. Includes 4-20mA and relay outputs. FM and CSA approvals.

5H1B02-AADBAAA00000A
(139)

ENDRESS+HAUSER  5H1B02-AADBAAA00000A

EH Proline Promag H 100 Electromagnetic Flowmeter for the smallest flow rates with ultra compact transmitter. 0.06 dm3/min to 600 m3/h measuring range. DN 2 Nominal Diameter. IP66/IP67. Aluminum (AlSi10Mg) housing. 24 VDC. Includes 4-20ma and switch outputs. Optional 4 line backlit display and Modbus RS485 communication. ATEX, IECEx, cCSAus, INMETRO and EAC approvals.

5H3B02-AAIBAAAAAA00000AA1
(415)

ENDRESS+HAUSER  5H3B02-AAIBAAAAAA00000AA1

EH Proline Promag H 300 Electromagnetic Flowmeter with compact transmitter for hygienic applications. 0.06 dm/min to 600 m/h measuring range. DN 02 Nominal Diameter. IP66/IP67. Aluminum (AlSi10Mg) or stainless steel housing. Includes 4-20ma, pulse/frequency/switch and double pulse outputs. ATEX, IECEx, cCSAus and INMETRO approvals.

7F2C15-AAAACAAAAAAAASKA1
(143)

ENDRESS+HAUSER  7F2C15-AAAACAAAAAAAASKA1

EH Proline Prowirl F 200 Vortex Flowmeter with wet steam detection for heavy duty applications. Compact or remote version. 0.16 to 2412 m3/h measuring range. DN15 Nominal Diameter. Aluminum (AlSi10Mg) housing. IP66/IP67. Includes 4-20ma and switch outputs and 4-line backlit display. ATEX, IECEx and cCSAus approvals.

5H2B15-AAAACA00000A
(414)

ENDRESS+HAUSER  5H2B15-AAAACA00000A

EH Proline Promag H 200 Electromagnetic Flowmeter with loop-powered technology for smallest flow rates. 0.06 dm/min to 300 m/h measuring range. DN 15 Nominal Diameter. IP66/IP67. Aluminum (AlSi10Mg) housing. Includes 4-20ma and pulse/frequency/switch outputs. ATEX, IECEx, cCSAus and INMETRO approvals.

5E1B80-AADBAAA8A1KGA
(413)

ENDRESS+HAUSER  5E1B80-AADBAAA8A1KGA

EH Proline Promag E 100 Electromagnetic Flowmeter with ultra-compact transmitter. 4 dm/min to 9600 m/h measuring range. DN 80 Nominal Diameter. 24VDC. IP66. Aluminum (AlSi10Mg) housing. Includes 4-20ma and pulse/frequency/switch outputs. Optional Modbus RS485 communication. ATEX, IECEx, cCSAus and INMETRO approvals.

5H5B15-AAIBAAAAFAAAAA00000AA1
(416)

ENDRESS+HAUSER  5H5B15-AAIBAAAAFAAAAA00000AA1

EH Proline Promag H 500 Electromagnetic Flowmeter for hygienic applications as remote version with up to 4 I/Os. 0.06 dm/min to 600 m/h measuring range. DN 15 (1/2") Nominal Diameter. IP66/IP67. Aluminum (AlSi10Mg) housing. Includes 4-20ma, pulse/frequency/switch and relay outputs. ATEX, IECEx, cCSAus and INMETRO approvals.

5P1B15-AADBAAAEA1KGA
(138)

ENDRESS+HAUSER  5P1B15-AADBAAAEA1KGA

EH Proline Promag P 100 Electromagnetic Flowmeter for highest medium temperatures with ultra-compact transmitter. 4 dm3/min to 9600 m3/h measuring range. DN 15 Nominal Diameter. IP66/IP67. Aluminum (AlSi10Mg) housing. 24VDC. PTFE Liner. Includes display, 4-20ma and switch outputs. Optional Modbus RS485 communication. ATEX, IECEx, cCSAus and INMETRO approvals.

5P3B15-AAIBAAAAAAEA1KGAA1
(407)

ENDRESS+HAUSER  5P3B15-AAIBAAAAAAEA1KGAA1

EH Proline Promag P 300 Electromagnetic Flowmeter for highest medium temperatures with compact transmitter. 4 dm3/min to 9600 m3/h measuring range. DN 15 Nominal Diameter. IP66/IP67. Aluminum (AlSi10Mg) housing. PTFE Liner. Includes display, 4-20ma, switch, double pulse and relay outputs. Optional Modbus RS485 communication. ATEX, IECEx, cCSAus and INMETRO approvals.

9B2B80-AAAACA1W0W1
(141)

ENDRESS+HAUSER  9B2B80-AAAACA1W0W1

EH Proline Prosonic Flow B 200 Ultrasonic Flowmeter for biogas measurement with loop-powered technology. 1 to 30 m/s measuring range. DN 80 Nominal Diameter. IP66/IP67. Aluminum (AlSi10Mg) housing. Includes 4-20ma and switch outputs. Optional 4-line backlit display. ATEX, IECEx, cCSAus, NEPSI and INMETRO approvals.

8FE08-AAASAABAA10N
(147)

ENDRESS+HAUSER  8FE08-AAASAABAA10N

EH LPGmass Coriolis Flowmeter for measurement of LPG. 0 to 45000 kg/h measuring range. DN8 Nominal Diameter. Aluminum housing. IP67 type 4X Enclosure. 10-30VDC, 20-28VAC. Includes switch outputs and Modbus RS485 communication. ATEX, IECEx, NEC/CEC, FM, CSA, NEPSI and UL approvals.

8FF08-AG15AABAA10N
(145)

ENDRESS+HAUSER  8FF08-AG15AABAA10N

EH CNGmass Coriolis Flowmeter with the highest accuracy. 0 to 150 kg/min measuring range. DN8 Nominal Diameter. G1/2" female thread. Aluminum housing. IP67 type 4X Enclosure. Includes switch outputs and Modbus RS485 communication. ATEX, IECEx, NEC/CEC, FM, CSA, NEPSI and UL approvals.

8F1B08-AADBAAASAAASA
(140)

ENDRESS+HAUSER  8F1B08-AADBAAASAAASA

EH Proline Promass F 100 Coriolis Flowmeter with premium accuracy, robustness and ultra-compact transmitter. 0 to 2200000 kg/h measuring range. DN 8 Nominal Diameter. IP66/IP67. Aluminum (AlSi10Mg) housing. Includes 4-20ma and switch outputs. Optional 4-line backlit display and Modbus RS485 communication. ATEX, cCSAus and IECEx approvals.

8P1B15-AADBAAABBAAWA
(411)

ENDRESS+HAUSER  8P1B15-AADBAAABBAAWA

EH Proline Promass P 100 Coriolis Flowmeter with ultra-compact transmitter for applications in sterile environments. 0 to 70000 kg/h measuring range. DN 08 Nominal Diameter. 24VDC. IP66/IP67. Aluminum (AlSi10Mg) housing. Includes 4-20ma, switch, pulse and frequency outputs. Optional Modbus RS485 communication. ATEX, IECEx, cCSAus and INMETRO approvals.

83E50-AAASAAAAAAAA
(189)

ENDRESS+HAUSER  83E50-AAASAAAAAAAA

EH Proline Promass 83E Coriolis flowmeter with extended transmitter functionality for highly accurate measurement of liquids and gases. 0 to 180000 kg/h measuring range. DN 50 Nominal Diameter. IP67 type 4X Enclosure. Includes 0-20 mA, 4-20 mA, switch and relay outputs. Touch control and four line display. ATEX, IECEx, FM and CSA approvals.

8F3B25-AAIBAAAAAASAAASAA1
(408)

ENDRESS+HAUSER  8F3B25-AAIBAAAAAASAAASAA1

EH Proline Promass F 300 Coriolis Flowmeter with highly accurate sensor and robust compact transmitter. 0 to 2 200000 kg/h measuring range. DN 25 Nominal Diameter. IP66/IP67. Aluminum (AlSi10Mg) housing. Includes display, 4-20ma, switch, double pulse and relay outputs. Optional Modbus RS485 communication. ATEX, IECEx, cCSAus and INMETRO approvals.

8DF08-AG15AAAAA70M
(146)

ENDRESS+HAUSER  8DF08-AG15AAAAA70M

EH CNGmass DCI Coriolis Flowmeter. 0 to 150 kg/min measuring range. DN8 Nominal Diameter. G1/2" female thread. Aluminum housing. IP67 type 4X Enclosure. Includes 0-20mA, 4-20mA and switch outputs and Modbus RS485 communication. ATEX, IECEx and NEC/CEC approvals.