EH Proline Promag W 300 Electromagnetic Flowmeter with compact transmitter for water and wastewater applications. 9 dm³/min to 162 000 m³/h measuring range. DN 25 Nominal Diameter. IP66/IP67. Aluminum (AlSi10Mg) housing. Includes 4-20ma, switch, double pulse and relay outputs. Optional Modbus RS485 communication. ATEX and cCSAus approvals.
Approval: Transmitter & Sensor
AA-Non hazardous area BB-ATEX+IECEx; Z1/21, Ex de, IIC/IIIC BD-ATEX+IECEx; Z1/21, Ex d, IIC/IIIC BS-ATEX+IECEx; Z2, IIC CD-CSA C/US; Cl.I,II,III Div.1, XP, Gr.A to G CS-CSA C/US; Cl.I Div.2, NI CZ-CSA C/US; Z2, IIC C2-CSA C/US; Z1/21, Ex de, IIC/IIIC C4-CSA C/US; Z1/21, Ex d, IIC/IIIC
(1) Approval: Transmitter & Sensor for EH Promag W300
Design
E-Fixed flange D-Lap joint flange 9-Special version, TSP no. to be spec.
(2) Design for EH Promag W300
Power Supply
D-24VDC E-100 to 230VAC I-100 to 230VAC/24VDC 9-Special version, TSP no. to be spec.
(3) Power Supply for EH Promag F300/P300
Output
BA-4 to 20mA HART CA-4 to 20mA HART Ex i passive GA-PROFIBUS PA HA-PROFIBUS PA Ex i LA-PROFIBUS DP MA-Modbus RS485 NA-EtherNet/IP 2 port switch integrated RA-PROFINET 2 port switch integrated SA-FOUNDATION Fieldbus TA-FOUNDATION Fieldbus Ex i 99-Special version, TSP no. to be spec.
(4) Output for EH Promag W300
Output 2 & 3
A-W/o; B-4 to 20mA C-4 to 20mA Ex i passive D-Configurable I/O default off E-Pulse/freq./switch output F-Pulse output, phase shifted G-Pulse/freq./switch output Exi passive H-Relay I-4 to 20mA input J-Status input 9-Special version, TSP no. to be spec.
(5) Output 2 & 3 for EH Promag P300/W300
Output 2 & 3
A-W/o; B-4 to 20mA C-4 to 20mA Ex i passive D-Configurable I/O default off E-Pulse/freq./switch output F-Pulse output, phase shifted G-Pulse/freq./switch output Exi passive H-Relay I-4 to 20mA input J-Status input 9-Special version, TSP no. to be spec.
(6) Output 2 & 3 for EH Promag P300/W300
Display & Operation
A-W/o; via communication F-4 line illum.; touch control G-4 line illum.; touch control + WLAN M-W/o; prepared for remote display O-Remote display 4 line illum., 10m/30ft cable; touch control 9-Special version, TSP no. to be spec.
(7) Display & Operation for EH Promag W300
Electrical Connection
A-Gland M20 B-Thread M20 C-Thread G1/2 D-Thread NPT1/2 L-Thread NPT1/2 + 1x plug M12x1 M-Gland M20 + 1x plug 7/8" N-Gland M20 + 1x plug M12x1 P-Thread G1/2 + 1x plug M12x1 R-Gland M20 + 2x plug M12x1 S-Thread NPT1/2 + 2x plug M12x1 T-Thread G1/2 + 2x plug M12x1 U-Thread M20 + 1x plug M12x1 V-Thread M20 + 2x plug M12x1 3-Thread M20 + 1x plug 7/8" 4-Thread G1/2 + 1x plug 7/8" 5-Thread NPT1/2 + 1x plug 7/8" 6-JPN Ex d Thread G1/2 9-Special version, TSP no. to be spec.
(8) Electrical Connection for EH Promag P300/W300
Liner
U-Polyurethane Q-PTFE 90oC 9-Special version, TSP no. to be spec.
(9) Liner for EH Promag W300
Process Connection
A1K-Cl.150, carbon steel, flange ASME B16.5 A1S-Cl.150, stainl. steel,flange ASME B16.5 A12-Cl.150, carbon steel, lap joint flange ASME B16.5 A14-Cl.150, stainl. steel, lap joint flange ASME B16.5 A2K-Cl.300, carbon steel, flange ASME B16.5 A2S-Cl.300, stainl. steel, flange ASME B16.5 D21-PN10, carbon steel, lap joint flange, stamped plate EN10921 D23-PN10, stainl. steel, lap joint flange, stamped plate EN10921 D32-PN16, carbon steel, lap joint flange EN10921 D34-PN16, stainl. steel, lap joint flange EN10921 D5K-PN40, carbon steel, flange EN10921 D5S-PN40, stainl. steel, flange EN10921 N4K-20K, carbon steel, flange JIS B2220 N4S-20K, stainl. steel, flange JIS B2220 999-Special version, TSP no. to be spec.
(10) Process Connection for EH Promag W300
Electrodes
G-1.4435/316L, bullet nose H-Alloy C22, bullet nose 0-1.4435/316L 1-Alloy C22 2-Tantalum 9-Special version, TSP no. to be spec.
(11) Electrodes for EH Promag W300
Calibration Flow
A-0.5% B-0.2% D-0.5%, 3 point, traceable ISO/IEC 17025 E-0.2%, 3 point, traceable ISO/IEC 17025 F-0.5% Flat Spec. G-0.2% Flat Spec. M-0.5%, 3 point N-0.2%, 3 point 9-Special version, TSP no. to be spec.
(12) Calibration Flow for EH Promag W300