EH CCS240 Analog disinfection sensor for standard measurement of Chlorine Dioxide (Cl2) 0,05 - 20ppm. Amperometric and membrane-covered. NTC-temperature sensor.

Part# with Options:        CCS240-N
Price with Options:        Please Email us your request for quote   

Options:    

Version
(1) Version for EH CCS240

  Availability 7 Days  ]

Sensors for chlorine dioxide

Amperometric, membrane-covered sensors for installation in the CCA250 assembly

Application

Chlorine dioxide is used for disinfection of water. Its dosing must be carefully controlled to suit the application. Too low a concentration makes the degree of disinfection questionable.

Too high a concentration can result in corrosion effects, impairment of taste or skin irritation.

The CCS240 and CCS241 sensors are applied for measurement of chlorine dioxide in the following fields:

  • Drinking water treatment
  • Pool water treatment
  • Industrial water treatment
Your benefits
  • Measurement in the CCA250 flow assembly is almost independent of flow rate in the range above 30 l/h
  • No zero point calibration necessary. This means complicated installation of an active carbon filter, as in open chlorine dioxide sensors, is not necessary.
  • Measured values are not affected by conductivity fluctuation of the medium.
  • The CCS240 sensor is ready for measurement after a polarisation time of approx. 10 ... 30 minutes. The CCS241 sensor requires 45 ... 90 min.
  • Easy membrane replacement thanks to ready-made membrane head
  • Recalibration intervals approx. 1 ... 4 months under constant operating conditions
Function

The CCS240 and CCS241 sensors are used for measurement of chlorine dioxide. The membrane-covered CCS240 / CCS241 sensors consist of a cathode serving as the working electrode and an anode acting as the counter electrode. These electrodes are immersed in an electrolyte. Electrodes and electrolyte are separated from the medium by a membrane. The membrane prevents the loss of electrolyte and the penetration of contaminants.

To calibrate the measuring system, determine the content of chlorine dioxide using the DPD method. You need a photometer with the pertaining reagents. The determined value is the calibration value for the transmitter.

Measuring Principle

The concentration of chlorine dioxide is determined according to the amperometric measuring principle. The chlorine dioxide (ClO 2 ) contained in the medium diffuses through the sensor membrane and is reduced to chloride ions (Cl - ) on the gold cathode. On the silver anode, silver is oxidized to silver chloride. The electron release of the gold cathode and electron acceptance on the silver anode result in a current flow which is proportional to the chlorine dioxide concentration in the medium. This process takes place within a wide pH and temperature range.

Measuring system

A complete measuring system comprises at least:

  • Chlorine dioxide sensor
  • Liquisys M CCM223/253 transmitter
  • Special measuring cable
  • Flow assembly
  • Reference measuring instrument for determination of chlorine dioxide according to the DPD method

Measuring Principle Chlorine dioxide
Application Waste water, pool
Characteristic Amperometric measurement of dissolved Chlordioxide
Measurement range 0,05 - 20ppm Chlordioxide;
Measuring principle - closed (membrane covered) measuring cell.
- Reduction of Chlordioxid (ClO2) to Chlorid at the cathode at appr. 120mV.
Design Closed amperometric 2-electrode measuring cell with PTFE membrane
Material Sensor shaft : PVC
Membrane : PTFE
Membrane cap : PBT (GF30); PVDF
Dimension Diameter : appr. 25mm
Length : 160mm
Process temperature 2C ... 45C
Process pressure 0bar - 1bar
temperature sensor With NTC-temperature sensor
Connection Fixed cable
Export Info
Made inGermany

  • ANALYSIS > TRANSMITTERS
    CCM223-EK0005 EH Liquisys CCM223 Disinfection transmitter for use with all analog total chlorine, free chlorine, chlorine dioxide and pH sensors. 0/4-20 mA, HART and PROFIBUS interfaces. IP54. ..

  • ANALYSIS > TRANSMITTERS
    CCM253-EK0005 EH Liquisys CCM253 Disinfection transmitter for use with all analog total chlorine, free chlorine, chlorine dioxide and pH sensors. 0/4-20 mA, HART and PROFIBUS interfaces. IP65. CSA Approval. ..

  • CHLORINE ANALIZERS > ASSEMBLY
    CCA250-A0 EH Flowfit CCA250 Flow assembly for free chlorine measurement in drinking, industrial and pool water. Designed to accommodate chlorine, pH and ORP sensors. Plexiglas Housing. ..

  • CHLORINE SENSORS > GENERAL PURPOSE
    CCS241-N EH CCS241 Analog disinfection sensor for trace measurement of Chlorine Dioxide (Cl2) 0,01 - 5ppm. Amperometric and membrane-covered. NTC-temperature sensor. ..


B2B Checkout Options: Designated Carrier and Tax-Exempt purchase
Payment Options: Credit Card, Credit Card Over the Phone, PAYPAL, Wire Transfer, Check and Money Order

Checkout with Paypal

> GENERAL PURPOSE :    47 Items found.
CUE25-A
(319)

ENDRESS+HAUSER  CUE25-A

EH Turbimax CUE25 Handheld turbidity meter for on-site quality control. Infrared Measurement. 00.01-1100 NTU/FNU measurement range. ABS NEMA4X Housing. IP67.



 
OUSAF11-AA105A1A10A
(323)

ENDRESS+HAUSER  OUSAF11-AA105A1A10A

EH OUSAF11 Glass-free Optical sensor for the measurement of VIS/NIR absorption, changing phases and suspended solids. G1 and NPT Process Connection. 390-1100 nm wavelenght range. 0-3 AU measurement range.

CCS241-N
(328)

ENDRESS+HAUSER  CCS241-N

EH CCS241 Analog disinfection sensor for trace measurement of Chlorine Dioxide (Cl2) 0,01 - 5ppm. Amperometric and membrane-covered. NTC-temperature sensor.

CAT810-AAD1A11
(337)

ENDRESS+HAUSER  CAT810-AAD1A11

EH Liquiline System CAT810 automatic system for online monitoring of sample conditioning from pressurized pipes and outlets. Self-cleaning backflush filter. Colorimetric measurement. Memosens technology. CSA Approval.

CLD132-PMV110AA1
(169)

ENDRESS+HAUSER  CLD132-PMV110AA1

EH Smartec CLD132 toroidal system for inductive conductivity measurement in hygienic applications. Includes compact transmitter and Stainless steel Pt100 temperature sensor. 100 S/cm - 2000 mS/cm measurement range. Relay output and 2-line display. IP67.

CUS51D-AAC1A2
(182)

ENDRESS+HAUSER  CUS51D-AAC1A2

EH Turbimax CUS51D memosens smart sensor for suspended solids and turbidity measurement in water, wastewater and utilities applications. Self-cleaning functionality. Corrosion and moisture resistant. 0 to 150g/l measurement range. Stainless steel sensor. G1 and NPT3/4 connection. IP68.

CUE24-A
(318)

ENDRESS+HAUSER  CUE24-A

EH Turbimax CUE24 laboratory turbidity meter for quality control. White Light measurement. 0 - 1000 NTU measurement range. RS232 Output. ABS Housing.



 
COS81D-AAA2CB11
(352)

ENDRESS+HAUSER  COS81D-AAA2CB11

EH Memosens COS81D Digital optical sensor for Oxygen (O2) in Hygienic applications. 0,004 to 30 mg/l measurement range. Stainless steel sensor body. 0 to 190 psi process pressure. Pt100 temperature sensor. ATEX, CSA and IECEx approvals.

CUE21-A1A
(185)

ENDRESS+HAUSER  CUE21-A1A

EH Turbimax CUE21 online turbidity meter with sample condition adjustment. Infrared Measurement. 0 - 1000 NTU measurement range. 100-240 VAC. 4-20 mA or RS-485 output. Automatic ultrasonic cleaning function. ABS Housing. IP66.



 
CUE22-A1A
(186)

ENDRESS+HAUSER  CUE22-A1A

EH Turbimax CUE22 online turbidity meter with sample condition adjustment. White Light Measurement. 0 - 100 NTU measurement range. 100-240 VAC. Automatic ultrasonic cleaning function. ABS Housing. IP66.



 
OUSBT66-AA05A1A
(324)

ENDRESS+HAUSER  OUSBT66-AA05A1A

EH OUSBT66 Cell growth and biomass sensor for the measurement of Hygienic NIR absorption in fermentation and crystallization applications. 0-4 AU measurement range. LED light source. IP68.

CUS52D-AA1AA2
(314)

ENDRESS+HAUSER  CUS52D-AA1AA2

EH Turbimax CUS52D Hygienic Memosens Immersion Smart sensor for low and medium turbidity measurement in water. Self-cleaning functionality. 0 to 4000FNUY/NTU measurement range. Stainless steel sensor. G1 and NPT3/4 connection. IP68.

CUS71D-AA1A
(315)

ENDRESS+HAUSER  CUS71D-AA1A

EH Turbimax CUS71D Ultrasonic Memosens Immersion Smart sensor for sedimentation tanks. 0.3 - 10 m measurement range. ABS Epoxy sensor. IP68. CE certification.

CAS40D-AA1A1A1
(339)

ENDRESS+HAUSER  CAS40D-AA1A1A1

EH ISEmax CAS40D digital memosens Ion-sensitive sensor for continuous measurement of ammonium and nitrate in the wastewater industry. Self-cleaning functionality. Temperature sensor.

CUE23-A
(317)

ENDRESS+HAUSER  CUE23-A

EH Turbimax CUE23 laboratory turbidity meter for quality control. Infrared measurement. 0 - 1000 NTU measurement range. RS232 Output. ABS Housing.



 
OUSAF46-A0A0
(405)

ENDRESS+HAUSER  OUSAF46-A0A0

EH OUSAF46 Optical sensor combined with OUA260 flow assembly for the measurement of UV absortion. 0-2,5 AU measurement range. ATEX, FM, SIP and CIP approvals. IP65.

CAT820-AAE11A2A100A
(335)

ENDRESS+HAUSER  CAT820-AAE11A2A100A

EH Liquiline System CAT820 automatic in-situ filtration system for control of sample conditioning in wastewater treatment plants. Colorimetric measurement. Memosens technology. CSA Approval.

CAS51D-AAA1A2
(338)

ENDRESS+HAUSER  CAS51D-AAA1A2

EH Viomax CAS51D digital memosens photometric sensor for optical nitrate or SAC measurement in water, wastewater and utilities. Self-cleaning functionality. IP68.

CAT860-AAE11A2A100TA
(336)

ENDRESS+HAUSER  CAT860-AAE11A2A100TA

EH Liquiline System CAT860 automatic in-situ filtration system for control of sample conditioning from inlets in wastewater treatment plants. Colorimetric measurement. Memosens technology. CSA Approval.

CA80CR-AAAF1C101
(359)

ENDRESS+HAUSER  CA80CR-AAAF1C101

EH Liquiline System CA80CR Colorimetric analyzer for online measurement of Chromate (Cr(VI)) with Memosens technology. 2 0/4-20 mA outputs, up to 2 measuring channels and up to 4 digital sensor inputs. CSA Approval.

Page: 1 | 2 | 3 | All